Controlled by single chip microcomputer, temperature accuracy +/- 0.03 ℃, kinematic viscosity measurement range 0.5~ 20000mm ²/s, automatic tracking of heating Linear dispersion and precise control of water Bath and oil Bath temperature.
Using 10L Glass Bathtub, small size and less medium consumption, temperature control accuracy of +/- 0.05 ℃, automatic accurate timing and viscosity calculation, support 4 holes at the same time experiment, easy and reliable operation.
Ubbelohde DIN standard design, viscosity measurement range of 100-500cSt, based on the principle of capillary tubing flow time proportional to viscosity, to ensure accurate determination of liquid kinematic viscosity.
The instrument adopts Precision Platinum Resistance Sensor with temperature control accuracy of +/- 0.1 ℃ and kinematic viscosity measurement range of 0~ 10000mm ²/S, which is suitable for viscosity analysis of various liquids under thermostatic conditions.
Applicable to the flow time of not less than 20 seconds viscosity measurement, using aluminum material, capacity 50ml, flow hole diaMeter 5.6mm, can be converted into kinematic viscosity.
Using Cannon-Fenske opaque design, suitable for opaque liquid measurement, viscosity measurement range of 240~ 1200cSt, High Accuracy viscosity detection based on capillary tubing outflow time method.
Ubbelohde ASTM standard design, viscosity measurement range of 20-100cSt, based on the principle of capillary tubing can accurately determine the kinematic viscosity of liquids, suitable for a variety of fluid analysis.
Ubbelohde DIN standard design, viscosity measurement range of 0.35~ 1cSt, based on the principle of capillary tubing flow time proportional to viscosity, to ensure High Accuracy and Repeatability.
Using PID intelligent temperature control technology, Precision temperature control up to +/- 0.1 ℃, equipped with 7-inch Touchscreen and four-hole test position, automatically calculate viscosity and store 50 sets of data, easy and efficient operation.
U-shaped tube design, viscosity measurement range of 60-300cSt, based on the principle of capillary tubing to achieve accurate measurement of liquid kinematic viscosity and outflow time.
Ubbelohde ASTM standard design, viscosity measurement range of 1~ 5cSt, based on the principle of capillary tubing liquid flow time is proportional to viscosity, suitable for accurate determination of a variety of liquid samples.
The stainless steel material is corrosion resistant, the flow hole diaMeter is 4mm and the capacity is 100ml. The portable design is easy to use, suitable for coating viscosity measurement, and the outflow time is accurate in the range of 30-100 seconds.
Copper Cup with bracket structure, capacity 100 +/- 1ml, flow hole diaMeter 4mm, applicable to the flow time of 150 seconds or less viscosity test, through the flow time conversion kinematic viscosity value.
U-tube countercurrent design, viscosity measurement range of 60~ 300cSt, based on the principle of capillary tubing, viscosity is calculated by measuring liquid outflow time to ensure High Accuracy and Repeatability.
U-tube countercurrent design, viscosity measurement range of 6~ 30cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity, suitable for a variety of liquid sample analysis.