Automatic Preparator

The automatic preparator uses robotic arms and program control to complete operations such as sample weighing, dilution, and mixing, replacing manual handling of liquids or powders. It is used in laboratories for the batch preparation of standard solutions, coating test samples, etc., reducing human errors and improving reproducibility.
Selection
When selecting an automatic preparator, it is essential to match the sample form and throughput requirements, verify the precision range and compatibility with container specifications, focus on cleaning designs to prevent cross-contamination, consider the software operation logic and integration with existing equipment, and evaluate maintenance cycles and consumable costs.

Terms

Standards

Instruments

Controlled by single chip microcomputer, temperature accuracy +/- 0.03 ℃, kinematic viscosity measurement range 0.5~ 20000mm ²/s, automatic tracking of heating Linear dispersion and precise control of water Bath and oil Bath temperature.

$ 2116.00

Adopt automatic mechanical pressurization and curing inlay program, Heating power 650W, mold sleeve specification is 40mm, realize automatic heating and pressurization and automatic pressure relief after molding, real-time temperature display to ensure stability and reliability.

$ 3612.00

Adopt automatic mechanical pressurization and heating technology, mold sleeve specification is 30mm, Heating power 650W, automatic pressing and shutdown pressure relief, real-time temperature display, support room temperature sampling, suitable for thermoset material inlay.

$ 3612.00

Using high-resolution digital camera for automatic detection and playback function, can simultaneously measure three capillary tubing, temperature control using platinum resistance to improve accuracy, with automatic and manual visual two measurement modes.

$ 4188.00

Using photoelectric automatic equilibrating principle, measurement range +/- 45 ° optical rotation and +/- 120 ° Z sugar content, minimum reading +/- 0.001 °, equipped with color LCD Touchscreen and USB interface, support automatic retest 6 times and calculate the average value.

$ 1752.00

Using photoelectric detection and automatic dial display, the measurement range is +/- 45 °, the minimum reading is 0.001 °, and the low optical rotation sample can be accurately analyzed, and the operation is simple.

$ 1380.00

The kit can realize automatic grinding fineness Gauge operation, improve test Repeatability, suitable for standard scraper fineness Meter supporting use, simplify the experimental process.

$ 1623.00

Using ARM microprocessor and color liquid crystal display, with automatic heating sweep ignition function, Temperature range 40~ 400 ℃, can store 1000 measurement results, support atmospheric pressure correction and forced Air-Cooled.

$ 2116.00

Using automatic mechanical pressurization and heating technology, the inlay process is completed automatically, the Heating power is 650W, and the mold sleeve specification is 25mm, which is suitable for edge protection of small irregular samples.

$ 3612.00

Adopt ARM microprocessor and color LCD display, with automatic heating, sweeping, ignition function, Repeatability ≤ 110 ℃ +/- 1 ℃, support atmospheric pressure correction and forced Air-Cooled, easy and reliable operation.

$ 2116.00

Spreader thickness range 1~ 571.5μm, accuracy +/- 0.001mm, speed 5~ 200mm/s, with automatic feeding and stirring function, can customize a variety of coating methods.

$ 6205.00

Measurement range 0-200mN/m, accuracy +/- 0.02mN/m, support Automatic calibration and temperature compensation, real-time display test Linear dispersion and export Excel data.

$ 4188.00

Measurement range 0~ 14.00pH and accuracy +/- 0.01pH, built-in automatic polarity reversal circuit, automatic tracking end point potential, no need to manually switch, easy to operate and precise control.

$ 420.00

Adjustable application width, with automatic Spreader function, easy to operate, Repeatability is good, suitable for a variety of samples of laboratory prepative.

$ 4914.00

High-resolution digital camera for automatic detection, can simultaneously measure 3 capillary tubing samples, Temperature range RT +~ 400 ℃, with automatic measurement and manual visual two functions, support data storage and export.

$ 4188.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Application of Laboratory Coating Machines in the Coating of Optical-Grade PET Anti-Reflection Coatings
This article discusses the application of laboratory coating machines in the preparation of anti-reflective coatings on optical-grade PET substrates. By controlling parameters such as coating speed and gap, the coating machine enables precise adjustment of coating thickness, thereby enhancing light transmittance and reducing reflection.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium Battery Separators
This article introduces the application of automatic coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Differential Scanning Calorimetry for Measuring the Melting Temperature of Thin Films
Differential scanning calorimetry analyzes thermal transitions in materials by measuring the heat flow difference between the sample and a reference. When determining the melting temperature of thin films, the sample must be uniformly prepared, with a mass between 3 and 10 milligrams. Testing is typically conducted at heating rates ranging from 5 to 20°C/min under a nitrogen protective atmosphere.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.