Using dual-channel proportional value display, knob type operation is easy, flame size can be pre-selected, equipped with flameout protection device. Detection limit K ≤ 0.004mmol/L, Na ≤ 0.008mmol/L, Response Time < 8S, high stability.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, pass band is narrow, Sensitivity is high; Five elements can be combined with any combination at the same time, automatic ignition and flame monitoring, Response Time is less than 8 seconds, Stability change within 15 seconds ≤ 2%.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, the passband is narrow, and the Sensitivity is high; the five elements can be combined with any combination of direct reading measurement at the same time, the Response Time is less than 8 seconds, and the relative change of Stability in 15 seconds does not exceed 2%.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, Sensitivity is high; Five elements can be combined with any combination of direct reading measurement at the same time, flexible and convenient; Internal standard channel can correct the signal to ensure stable and reliable performance.
Dual-channel proportional value shows that the sample suction and spray volume is less than 6mL/min, the Response Time is less than 8 seconds, and it has a flameout protection device, which is easy, stable and reliable to operate.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, pass band is narrow, Sensitivity is high; Support any combination of five elements direct reading measurement, Response Time is less than 8 seconds, Stability relative change within 15 seconds ≤ 2%.
Dual channel LED digital display, Measurement accuracy, sodium detection limit ≤ 0.008mmol/L, support lithium calcium detection, using silicon Photocells, photovoltaic cells and liquefied petroleum gas fuel, sample volume is small and Sensitivity is high.
Using concave Holographic grating design, Light spectrum pure and accurate, narrow passband, Sensitivity is high; Five elements can be combined with any combination of direct reading measurement at the same time, Response Time is less than 8 seconds, Stability relative change within 15 seconds does not exceed 2%.
Using concave Holographic grating design, Light spectrum is pure, narrow passband, Sensitivity is high, linearity is better; Support any combination of five elements while direct reading measurement, automatic ignition and flameout protection function to ensure safety.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, narrow passband, high Sensitivity, good linearity; supports any combination of five elements for direct reading measurement, Response Time is less than 8 seconds, Stability change within 15 seconds ≤ 2%.
Dual channel LED digital display ensures clear reading, using silicon Photocell, photovoltaic cell detection to make the measurement results accurate and stable, Response Time is less than 8 seconds and has flameout protection function, safe and reliable operation.
Concave Holographic grating design, Light spectrum pure and accurate, narrow passband, Sensitivity; Support any combination of five elements direct reading measurement, Response Time is less than 8 seconds, with automatic ignition and flameout protection function.
Dual channel design can simultaneously detect potassium and sodium elements, detection limit potassium ≤ 0.004mmol/L, sodium ≤ 0.008mmol/L, with automatic calculation of correlation coefficient and flameout protection function, Response Time is less than 8 seconds.
Photocell, photovoltaic cell detection to ensure accurate and stable measurement, potassium and sodium detection limit of 0.004mmol/L and 0.008mmol/L, Response Time is less than 8 seconds, support lithium calcium detection function.
Dual channel LED digital display, potassium and sodium can be detected at the same time, lithium calcium function expansion, silicon Photocell, photovoltaic cell detection accuracy is high, Linearity ≤ 0.07, detection limit is as low as 0.004mmol/L, sample volume is small Sensitivity is high, flameout protection is safe and reliable.