Contour Measuring Instrument

The profilometer scans the surface of an object with a stylus, recording height variation data to form a contour curve. It is used to detect shape deviations on workpiece surfaces and control geometric parameters such as edge angles and arc radii in machining and mold manufacturing.
Selection
When selecting, consider that the measurement range covers the workpiece dimensions, the resolution meets tolerance requirements, the probe type is suitable for material hardness, environmental vibrations affect measurement stability, and the software functionality supports the required evaluation criteria.

Terms

Standards

Instruments

Optical inspection imagery and image contour analysis technology, Measurement accuracy of +/- 0.1 °, equipped with imported CCD camera and industrial-grade lens, support a variety of droplet state testing and dynamic contact angle fitting.

$ 3268.00

Using machine vision to automatically identify Baseline and droplet contour, based on Laplace equation quadratic Linear dispersion fitting calculation, Measurement accuracy of 0.1 °, support static drop method, droplet method and inclined plate method and other testing methods.

$ 3623.00

Dual channel LED digital display, using silicon Photocell, photovoltaic cell detection, measurement Repeatability relative standard deviation ≤ 2%, can simultaneously detect various elements of potassium, sodium, lithium, calcium and barium, the sample amount is small and Sensitivity is high.

$ 1493.00

Silicon Photocell, photovoltaic cell detection to ensure accurate and stable measurement, can simultaneously detect potassium, sodium, lithium, calcium and barium elements, small sample Sensitivity, with automatic ignition and flameout protection function safe and reliable.

$ 1493.00

Dual-channel LED digital display, Silicon Photocell, photovoltaic cell detection to ensure accurate and stable, potassium, sodium, lithium, calcium and barium multi-element simultaneous detection, Sensitivity is high and the sample amount is small, Linearity ≤ 0.07.

$ 1493.00

Dual channel LED digital display, potassium and sodium can be detected at the same time, lithium calcium function expansion, silicon Photocell, photovoltaic cell detection accuracy is high, Linearity ≤ 0.07, detection limit is as low as 0.004mmol/L, sample volume is small Sensitivity is high, flameout protection is safe and reliable.

$ 1493.00

Dual-channel LED digital display clear reading, button automatic ignition fast and reliable, can simultaneously detect potassium and sodium and support lithium calcium barium measurement, using silicon Photocell, photovoltaic cell detection accuracy, small sample Sensitivity, with flameout protection safety function.

$ 1493.00

Dual channel LED digital display, potassium and sodium detection and have lithium calcium function, using silicon Photocell, photovoltaic cell to ensure measurement Stability, small sample Sensitivity, with flameout protection safety design.

$ 2042.00

Dual channel LED digital display, potassium and sodium can be detected at the same time, lithium calcium detection function, silicon Photocell, photovoltaic cell detection is accurate and stable, the sample amount is small and Sensitivity is high, Linearity ≤ 0.005, detection limit ≤ 0.004.

$ 1493.00

The activated aluminum oxide ball is used as the adsorption medium, which can adsorption water vapor and chemical corrosion harmful gases, and the oil blocking rate is more than 99%.

$ 146.00

Dual channel LED display, automatic ignition design, using silicon Photocell, photovoltaic cell detection, Sodium Measurement range 0.0-200 mmol/L, Lithium Measurement range 0-15mmol/L, Sensitivity is high and the sample volume is small.

$ 1493.00

The principle of vacuum adsorption is used to ensure that the substrate is flat, the high-quality aluminum alloy material is matched with 176 vacuum holes, the hole spacing is 18mm, and the oil-free Vacuumpump power is 150W to achieve efficient and environmentally friendly Moulding operation.

$ 743.00

The device uses 1200-1500lx Illumrination degree, achieves 80x magnification and 0.01mm resolution through scale Microscope, and can measure the maximum aperture of 2mm, suitable for aluminum foil pinholing light transmission observation.

$ 554.00

Using PTFE pump head material and coating diaphragm, suitable for strong corrosive gases, pumping speed 20L/min, Ultimate vacuum degree 3~ 8mbar, with pressure relief and cleaning functions, good air tightness and noise less than 58dB.

$ 1579.00

Silicon Photocell, photovoltaic cell detection to ensure accurate and stable measurement, potassium and sodium detection limit of 0.004mmol/L and 0.008mmol/L, support lithium calcium detection function, small sample and Sensitivity.

$ 961.00

Articles

The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Gloss meter measures the gloss consistency of resin coating film surfaces.
This article introduces how to use a gloss meter to measure the gloss consistency of resin coating film surfaces.
Haze meter for detecting haze and light transmittance of optical-grade resin
This article introduces the basic concepts, measurement principles, and practical applications of haze and light transmittance in optical-grade resin materials.
Haze meter detects the transparent scattering characteristics of optical coatings.
This article introduces how a haze meter detects the transparency and scattering characteristics of optical coatings. Optical coatings are used in fields such as displays and packaging, where their transparency and scattered light can affect product performance.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Canadian Standard Freeness Tester for Measuring Pulp Drainage Performance
The Canadian Standard Freeness Tester is used to measure the drainage properties of pulp, which is an important indicator for evaluating pulp quality. Based on the principle of gravity filtration, the instrument measures the drainage rate of pulp suspension under standard conditions to determine the freeness value.
Use of pendulum hardness tester for paint film curing degree assessment in the laboratory.
The pendulum hardness tester evaluates the hardness of a paint film by measuring the decay time of a pendulum swinging on the surface of the film, where a longer time indicates a harder film and a higher degree of curing.
Surface Roughness Tester Evaluates the Impact of Substrate on Adhesion
This article primarily explores how the surface roughness of the substrate affects the adhesion of coatings or bonds.
Laser particle size analyzer analyzes particle size distribution of paint pigments.
This article introduces the application of laser particle size analyzers in analyzing the particle size distribution of paint pigments. It mentions that the particle size distribution of pigments affects the optical properties, stability, and rheological characteristics of coatings.
Principle and Application of Whiteness Meter in Measuring Coating Whiteness
A whiteness meter quantifies the whiteness of paint samples by simulating human perception of white, measuring the diffuse reflectance of light—particularly in the blue wavelength range—and converting it into a numerical whiteness value. It employs standardized optical configurations and mathematical models, such as the Ganz formula, to assess the brightness and chromaticity of coatings.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.