Non-contact Color Analyzer

Non-contact colorimeters capture the reflected light from an object's surface through an optical lens and analyze color data via a spectral analysis system. They are used to measure the color of liquids, powders, or uneven surfaces, avoiding sample contamination, and are employed in the paint and ink industries for online quality monitoring.
Selection
When selecting, consider the measurement distance to suit the production line layout, ensure the spectral range covers the required wavelengths, and verify that the analysis software is compatible with the existing system. Pay attention to the ability to resist ambient light interference, the stability of repeated measurements, and the probe material's resistance to on-site dust and oil contamination.

Terms

Instruments

D/8 standard non-contact test, measurement distance 3.0mm, the fastest 0.2 seconds to complete the measurement, support a variety of Color Space and Illuminant, suitable for automatic pRoduction line accurate Color quality control.

$ 8109.00

Using 45/0 ring lighting and concave grating spectroscopy technology, the measurement diaMeter is Φ 20mm, the non-contact measurement distance is 7.5mm, and the chromatic value Repeatability is within 0.03. Color difference formula and chroma index analysis are supported.

$ 8109.00

Adopt 45/0 structure, measurement Repeatability dE * ab ≤ 0.02, Inter-instrument Agreement dE * ab ≤ 0.25, support non-contact detection, waterproof and dustproof IP66, multiple communication interfaces, LED Illuminant long life.

$ 3946.00

Optical inspection structure of 45/0 °, non-contact distance of 7.5mm, measurement wavelength of 400-700nm, avoid sample contamination and damage, support a variety of Measurement modes and High Accuracy Color Analysis.

$ 7464.00

Non-contact automatic whiteboard calibration technology, Inter-instrument Agreement Delta E * 00 < 0.2, high measurement Stability, supports more than 30 Color indicators and 28 kinds of observation Illuminants, compact and easy to carry.

$ 332.00

Using 45/0 ring lighting and concave grating spectroscopy technology, measurement Wavelength range 400~ 700nm, non-contact distance 7.5mm, avoid sample contamination and damage, support a variety of Measurement modes and camera positioning.

$ 7464.00

Adopt 45/0 ° ring illumination and concave grating spectroscopy, measurement wavelength 400~ 700nm, non-contact distance 7.5mm, avoid sample contamination, support a variety of Measurement modes and camera positioning.

$ 8109.00

Non-contact measurement distance 7.5mm +/- 3mm fluctuation is still accurate, the measurement time is only 20ms, built-in auto calibration and Gloss compensation technology to ensure accurate and reliable Color data.

$ 12068.00

Using 45/0 ring illumination and concave grating spectroscopy technology, the measurement diaMeter is 20mm, and the non-contact distance is 7.5mm. With 256 pixel dual array CMOS sensor, Wavelength range 400~ 700nm, chromatic value Repeatability Delta E * ab 0.05, supports a variety of Color space and color difference analysis.

$ 7464.00

Non-contact measurement avoids contact with dangerous objects, Response Time 500ms Fast reading temperature, temperature range -32~ 550 ℃ covers a wide range of scenarios, compact structure and easy to operate.

$ 85.00

Adopt D/8 lighting mode and CMOS dual optical path sensor, measurement diaMeter Φ 8mm, Inter-instrument Agreement Delta E * 00 < 0.2, non-contact automatic whiteboard verification protection whiteboard, small size and easy to carry, support wireless connection expansion function.

$ 393.00

Repeatability Delta E * ab within 0.1, Measurement time of about 1.0 seconds; Non-contact automatic whiteboard calibration to avoid dirt, integrating ball double light path design to ensure stability, lightweight and portable can be continuously tested 12,000 times.

$ 234.00

Repeatability less than or equal to 0.05, display accuracy 0.01, non-contact automatic whiteboard calibration and integrating ball dual optical path design, Type-C interface can be continuously tested 12,000 times when fully charged.

$ 393.00

Repeatability Delta E * ab ≤ 0.08, display accuracy 0.01, equipped with non-contact automatic black and white plate calibration and integrating ball dual optical path sensor to ensure stable and accurate measurement, Type-C charging can be continuously tested 12,000 times.

$ 315.00

D/8 illumination observation conditions, measurement time 20ms, 0.5mm distance from the sample non-contact measurement, built-in black and white calibrate and ETC real-time calibrate technology to ensure high repeability and accuracy.

$ 11583.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Roughness Measurement Instrument Selection: Contact vs. Non-Contact
This article introduces the differences between contact and non-contact methods when selecting a roughness measuring instrument.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
Principles and Selection of Film Thickness Measurement Instruments
This article introduces the principles and selection methods of thin film thickness measurement instruments. The measurement principles are mainly divided into contact and non-contact methods, which calculate thickness by detecting the differences in the thin film's response to physical signals.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.