Adopt silent ozone generator and UltravioletDetector, ozone concentration control accuracy +/- 2pphm, support static tensile and dynamic tensile test, Temperature Uniformity ≤ 2 ℃ to meet a variety of test conditions
Adopt independent ozone concentration controller for long-term stable non-drift, equipped with high voltage silent discharge tube ozone generator, concentration range 10~ 1000pphm, Temperature Fluctuation +/- 0.5 ℃, support static tensile specimen and sample rack speed 1~ 2rpm.
Imported stainless steel liner and independent ozone concentration controller, temperature control accuracy of +/- 0.5 ℃, equipped with static tensile fixture and rotational speed adjustable sample rack, support long-term stable operation.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, temperature fluctuation is only +/- 0.5 ℃.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, Temperature Fluctuation control within +/- 0.5 ℃.
High Accuracy PID control technology, temperature fluctuation +/- 0.5 ℃, equipped with independent ozone concentration controller long-term stable non-drift, support static tensile specimen and program operation mode.
SUS304 stainless steel inner box and double insulation structure, equipped with 360 degree swirl/spin sample holder and precise ozone concentration control, temperature fluctuation +/- 0.5 ℃, support static dynamic tensile test, suitable for rubber durability research.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360-degree swirl/spin sample holder and 12-16mm/s gas flow rate, support 0-9999 hours time setting, with leakage overtemperature multiple safety protection.
The heating wire is used to achieve rapid heating, the temperature fluctuation is only +/- 0.5 ℃, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, supports dynamic static test mode, and meets a variety of test needs.
Using heating wire and PT100 temperature transducer, Temperature Fluctuation +/- 0.5 ℃, support 0~ 999H light time setting, 360 degree swirl/spin sample holder and imported concentration Analyzer to ensure test accuracy.
Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable, support 3~ 100 times/h ventilation volume adjustment, to meet a variety of aging test needs.
The 300W OSRAM bulb provides 365-400nm wavelength UV, Temperature Uniformity +/- 1 ℃, can be tested for yellowing resistance and aging at the same time, and the turntable Rotation speed 10 +/- 2rpm ensures uniform sample irradiation.
Adopt high temperature fan and special air duct to ensure temperature uniformity, equipped with low speed turntable; Temperature range RT + 10~ 200 ℃, uniformity +/- 2 ℃, support 3-100 times/h ventilation volume adjustment.
Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable and hot air circulation system to ensure stable and uniform temperature in the working room.
The use of high temperature fan and special air duct to achieve uniform heating, equipped with low-speed turntable to ensure uniform heating of the sample, Temperature Fluctuation control within +/- 0.5 ℃, ventilation can be adjusted within the range of 3-100 times/hour.