Using BNC connector design, equipped with 60mL reference filling solution and calibrated solution, provides stable potassium ion selective detection, suitable for laboratory water quality analysis.
With manual and automatic temperature compensation function, potassium Ion concentration Measurement range 0~ 39 g/L, resolution of 0.01 pK, easy to operate, digital display intuitive, light weight only 1.5kg.
Measurement range 0.000~ 0.3mg/L, can be 100 measurements, supporting special instruments to achieve fast and accurate water quality aluminum ion detection, including a variety of Reagent solutions.
Designed for potassium ion detection, 250ml standard Encasement can stabilize the ionic strength of the solution and ensure ElectRode Response performance, suitable for routine laboratory testing needs.
Dual channel LED digital display, using silicon Photocell, photovoltaic cell detection, measurement Repeatability relative standard deviation ≤ 2%, can simultaneously detect various elements of potassium, sodium, lithium, calcium and barium, the sample amount is small and Sensitivity is high.
Silicon Photocell, photovoltaic cell detection to ensure accurate and stable measurement, can simultaneously detect potassium, sodium, lithium, calcium and barium elements, small sample Sensitivity, with automatic ignition and flameout protection function safe and reliable.
Dual channel design can simultaneously detect potassium and sodium elements, detection limit potassium ≤ 0.004mmol/L, sodium ≤ 0.008mmol/L, with automatic calculation of correlation coefficient and flameout protection function, Response Time is less than 8 seconds.
Dual-channel LED digital display, Silicon Photocell, photovoltaic cell detection to ensure accurate and stable, potassium, sodium, lithium, calcium and barium multi-element simultaneous detection, Sensitivity is high and the sample amount is small, Linearity ≤ 0.07.
Silicon Photocell, photovoltaic cell detection to ensure accurate and stable measurement, potassium and sodium detection limit of 0.004mmol/L and 0.008mmol/L, support lithium calcium detection function, small sample and Sensitivity.
Dual channel LED digital display, potassium and sodium detection and have lithium calcium function, using silicon Photocell, photovoltaic cell to ensure measurement Stability, small sample Sensitivity, with flameout protection safety design.
Dual channel LED digital display, potassium and sodium can be detected at the same time, lithium calcium function expansion, silicon Photocell, photovoltaic cell detection accuracy is high, Linearity ≤ 0.07, detection limit is as low as 0.004mmol/L, sample volume is small Sensitivity is high, flameout protection is safe and reliable.
Photocell, photovoltaic cell detection to ensure accurate and stable measurement, potassium and sodium detection limit of 0.004mmol/L and 0.008mmol/L, Response Time is less than 8 seconds, support lithium calcium detection function.
Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.
Dual channel LED digital display, potassium and sodium can be detected at the same time, lithium calcium detection function, silicon Photocell, photovoltaic cell detection is accurate and stable, the sample amount is small and Sensitivity is high, Linearity ≤ 0.005, detection limit ≤ 0.004.
The activated aluminum oxide ball is used as the adsorption medium, which can adsorption water vapor and chemical corrosion harmful gases, and the oil blocking rate is more than 99%.