Penetration Probe Moisture Meter

The probe-type moisture meter measures the moisture content by contacting the sample with a metal probe and detecting changes in its conductivity or dielectric constant. It is used for rapid detection of moisture in solid or powdered materials, enabling on-site quality control during production processes in industries such as papermaking and plastics.
Selection
When selecting, consider matching the sample form with the probe length, ensuring the measurement range covers daily needs, the calibration function adapts to different materials, the protection level meets the usage environment, and the response speed aligns with the detection frequency requirements.

Terms

Standards

Instruments

Temperature range -50 to 300 ° C, Response Time of only 4 seconds, equipped with replaceable ultra-fast Response stainless steel penetration Probe, with CAL Check ™ Adjustment and battery error prevention system to ensure accurate and reliable measurement.

$ 309.00

Measurement principle of resistance method, accuracy of +/- 1%, equipped with 610mm detachable long probe, can measure different depths of grain moisture, support voice broadcast and a variety of function settings, suitable for a variety of grain moisture detection.

$ 97.00

Measurement range of 3.0-600 mm with 2MHz Frequency and 22mm diaMeter design, high penetration capability, suitable for thickness detection of a variety of good conductor materials.

$ 211.00

Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.

$ 1397.00

Measurement range 0-1000N penetration resistance, detection depth of 30 cm can be extended to 1.5 Meters, without the ring knife method can quickly obtain dry density data, complete the detection within 10 minutes.

$ 419.00

Support 0 °, 10 °, 30 ° multi-angle test, equipped with 250mL liquid discharge funnel and 500mL measuringflask, can meet the needs of sanitary napkins and diapers at the same time, such as slippery penetration, re-penetration and other penetration performance measurement.

$ 603.00

Using temperature and humidity compensation technology to improve measurement accuracy, probe Sensor can penetrate deep into the material, Measurement range 0.8-80%, Response Time is only 1 second, with error fine-tuning and Interface customization function.

$ 233.00

Using fixed K type stainless steel penetration type temperature sensor, Response Time 20 seconds, temperature range coverage -50.0 to 300 ℃, in line with IP65 waterproof standards, to ensure stable work in harsh environments.

$ 286.00

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

The penetration method is used for testing, a set of tests only takes 15-20 minutes, the measurement depth is 0-30cm, the accuracy is less than or equal to 0.25%, and there is no radioactive pollution.

$ 346.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Measurement range 0-80%, accuracy +/- (0.5% n + 0.5% n), support USB/RS-232/Bluetooth Data output method.

$ 241.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Articles

Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.