Light Intensity Recorder

The illuminance recorder converts light signals into electrical signals through photosensitive components to record environmental light intensity. It is used to monitor lighting conditions in places such as laboratories and printing workshops, ensuring a stable process environment.
Selection
When selecting, consider the range covering the ambient illumination levels, ensure accuracy meets testing standards, and verify the presence of data export functionality. Pay attention to matching the sensor type with the light source to be measured and ensure the housing's protection rating is suitable for the installation environment.

Terms

Standards

Instruments

Simultaneous measurement of UV intensity, energy and temperature, Light spectrum Response range 340nm-420nm, power range of 40000mW/cm ², equipped with high temperature protective cover to adapt to 100 ℃ environment, Support automatic and manual two Measurement modes.

$ 251.00

800L large-capacity liner, three-sided light without dead angle design, temperature control accuracy +/- 1 ℃ and support day and night different settings, six-level adjustable light intensity, support up to 360 hours of continuous and stable operation.

$ 6136.00

Light spectrum Response range 230-280nm, peak 254nm, measurement accuracy +/- 10%, equipped with magnetic attraction fixed and 1 Meter Probe line, can display MAX Maximum and current value simultaneously.

$ 420.00

Support Bluetooth wireless setting and download, waterproof depth of 30 Meters, memory can store 96000 Measured values, users can replace the battery by themselves, and have temperature threshold LED alarm function.

$ 235.00

Simultaneous measurement of UV radiation intensity and barrier rate, Light spectrum Response 260-380nm, power range 0-40000uW/cm ², automatic conversion barrier rate and direct display, Portable design is easy to use.

$ 149.00

Simultaneous measurement of energy, power and temperature, Light spectrum range 315nm-400nm, sampling speed up to 2048 times/second, Automatic and Manual Measurement modes supported, slim design for tight spaces.

$ 251.00

Simultaneous measurement of UV energy, intensity and temperature, support four-band UV Power measurement, Data storage up to 60,000 Power data, high temperature design can run for a long time in 100 ℃ environment, sampling speed up to 2048 times/second.

$ 990.00

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

Temperature range of 0~ 50 ℃ and light intensity of 0~ 12000LX, support five-level light regulation and 99-segment program control, using PID intelligent temperature control system and pressure equilibrating refrigeration technology to ensure long-term continuous and stable operation.

$ 2612.00

With 0.1 ℃ temperature resolution and +/- 1 ℃ uniformity, it supports day and night independent temperature and light settings, and the liner is made of stainless steel to ensure long-term stable operation.

$ 2182.00

Using 395nm wavelength LED Illuminant, Light intensity 0-100% adjustable, equipped with Water-Cooled system to ensure stable operation, support 10-50mm irradiation distance, maximum conveying speed of 6 m/min, suitable for fine curing process.

$ 3220.00

Water-Cooled cooling system, LED UV Illuminant with 395 nm wavelength and 700 W Power, Light intensity 0-100% adjustable, conveying speed 0-6 m/min adjustable, suitable for rapid curing of various UV materials.

$ 2284.00

With 254nm center wavelength measurement capability, Light spectrum Response Range 230-280nm, with dedicated UVC Probe to eliminate Miscellaneous band interference, support MAX Maximum recording function.

$ 538.00

Adopt PID control technology implementation temperature fluctuation +/- 0.5 ℃, with multi-level light adjustment function, support day and night independent setting, equipped with air duct ventilating system to ensure temperature uniformity +/- 1 ℃.

$ 2103.00

Microcomputer PID control technology, Temperature Fluctuation +/- 0.5 ℃, light intensity 0~ 12000LX adjustable, with air duct ventilating and internal dehumidification function to ensure uniform and stable temperature and humidity.

$ 1590.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
Electronic Tensile Testing Machine Measures the Right-Angle Tear Strength of Films
This article explains how to measure the right-angle tear strength of films using an electronic tensile testing machine. During the test, a film specimen with a right-angle notch is first clamped onto the testing machine and stretched at a constant speed. The machine records the changes in force during the tearing process.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Electronic universal testing machine measures film tensile strength.
This article introduces the method of measuring the tensile strength of thin films using an electronic universal testing machine. During the test, the machine applies tensile force to the film sample, records the maximum tensile force and displacement through sensors, and then calculates the tensile strength using a formula.
In the selection of illuminance meters, sensor type and measurement range are key considerations.
This article introduces the key points for selecting sensor types and measurement ranges when choosing an illuminometer.
Vicat Softening Point Tester evaluates the heat deformation resistance of resins.
The Vicat softening point tester is used to measure the thermal deformation resistance of resins. It heats and applies pressure to the specimen until it deforms by 1 millimeter, recording the temperature at that point as the softening point.
Peel strength tester measures the peel force of hot melt adhesive resin.
The peel strength tester is used to measure the adhesive properties of hot melt adhesive resins, simulating the actual peeling process by recording changes in force values through constant-speed stretching.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Adhesion Tester Pull-Off Method for Determining Adhesion Strength of Varnish
This article introduces the test method for measuring the adhesion strength of varnish using the pull-off method. It involves adhering test cylinders to the coating and substrate with adhesive, then vertically pulling them apart with an instrument to record the maximum pulling force and calculate the adhesion strength.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Internal Bond Strength Scott Tester for evaluating interlayer bonding force of paper.
This article introduces the method of evaluating the interlayer bonding strength of paper using a Scott tester. The interlayer bonding strength affects the printing and mechanical properties of paper. During testing, the instrument peels the paper vertically through an adhesive test head, records the energy required for separation, and calculates the internal bond strength.
Application of Paperboard Burst Strength Tester in Packaging Materials
The paperboard bursting strength tester is a detection device used to measure the ability of packaging materials such as paperboard to resist rupture under vertical pressure. During the test, the sample is clamped between annular clamps, and increasing pressure is applied via hydraulic or pneumatic means until rupture occurs. The maximum pressure value is recorded as the bursting strength.