Ubbelohde ASTM standard design, viscosity measurement range 6000-30000cSt, based on capillary tubing flow time and viscosity proportional principle, suitable for high temperature and high viscosity fluid determination.
Ubbelohde ASTM standard design, viscosity measurement range of 20000-100000cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity, to ensure accurate determination of high viscosity liquids.
It can automatically measure the dynamic and Static COF at the same time, using high-precision ball screw drive, the total error of the force measurement system is less than +/- 2%, the slider traverse speed is 100 +/- 10mm/min, and the performance stability testing is accurate.
It can automatically measure the dynamic and Static COF at the same time, and the total error of the force measurement system is less than +/- 2%. It adopts high-precision ball screw drive, stable performance, accurate test and convenient operation.
Ubbelohde ASTM standard design, viscosity measurement range of 100-500cSt, based on the liquid flow time in capillary tubing is proportional to the viscosity principle, to ensure accurate determination.
It can automatically measure the dynamic and static COF at the same time, with a force measurement range of 0~ 5N, using high-precision ball screw drive, and equipped with a micro-printer to print multiple sets of results and averages.
Ubbelohde ASTM standard design, viscosity measurement range of 10,000-50000cSt, based on the principle of capillary tubing flow time and kinematic viscosity proportional to ensure accurate determination of high viscosity liquids.
The device can measure 0~ 1 range of Coefficient of Friction, test force accuracy of +/- 0.001N, support stepless speed regulation to 550mm/min, suitable for a variety of standard tests, easy to operate, accurate and reliable data.
Using high-precision ball screw drive, the total error of the force measurement system is less than +/- 2%, and the dynamic and static COF can be automatically measured at the same time. The micro-printer can print multiple sets of results and the average value.
Based on the principle that the flow time of the liquid in capillary tubing is proportional to the viscosity, the Ubbelohde ASTM standard design is adopted. Measurement range covers 1000-5000cSt, which is suitable for accurate determination of liquids of different viscosities.
Ubbelohde ASTM standard design, viscosity measurement range of 6-30cSt, based on capillary tubing flow time and viscosity proportional principle to achieve accurate determination, suitable for a variety of liquid sample analysis.
Ubbelohde ASTM standard design, viscosity measurement range of 1~ 5cSt, based on the principle of capillary tubing liquid flow time is proportional to viscosity, suitable for accurate determination of a variety of liquid samples.
The test is automated by microcomputer control, equipped with a High Accuracy 0.001N Force Sensor, and the special drive system runs smoothly. It can simultaneously measure Static COF and Kinetic COF, and support statistical analysis of data.
Aperture 3.76mm, viscosity range 100-800cSt, outflow time 20-80 seconds, in line with ASTM standard design, suitable for rapid determination of medium viscosity pRoducts.
Ubbelohde ASTM standard design, viscosity measurement range of 2000 to 10000cSt, based on capillary tubing flow time and viscosity proportional principle, to ensure High Accuracy.