Paint Film Impact Testing Instrument

The paint film impact tester evaluates the impact resistance of coatings by allowing a weight to free-fall and strike the coated panel. It is used to assess the adhesion, flexibility, and damage of materials such as coatings and plastics under mechanical impact, and is applicable for quality control in industries such as automotive and furniture.
Selection
When selecting, consider the impact energy range matching test standards, check the adjustability of the weights; confirm the vertical accuracy of the guide columns; choose the impact head size based on the specimen thickness; ensure there is a structure to prevent secondary impact; verify that the calibration certificate complies with industry regulations.

Terms

Standards

Instruments

Impact height of 120 cm, hammer mass 1000g, no secondary rebound phenomenon after impact, punch diaMeter 16mm, can accurately determine the impact strength of the paint film.

$ 370.00

Impact height up to 120 cm, weight weight mass 1000g, no secondary rebound after impact, to ensure accurate and reliable test results, suitable for film impact performance evaluation.

$ 370.00

Impact performance of paint film can be accurately determined by using 1000g standard weight and 100cm adjustable impact height, 8mm diaMeter of punch, which meets the standard test requirements and is easy and reliable to operate.

$ 199.00

Impact height 40cm, drop weight mass 500g, the degree of damage to the paint film is assessed by steel ball Impact, and the digital grade shows the anti-Impact ability, which is suitable for standard testing.

$ 202.00

Impact height 0-50cm can be accurately adjusted, drop weight mass 1000g with the Φ 8mm punch, can accurately determine the film anti-Impact performance, easy to operate and Repeatability.

$ 240.00

Impact block weight 500 +/- 5g, ball diaMeter φ 14 Hardness HRc60-66, can accurately assess the damage grade of paint film.

$ 183.00

Impact height 0-100cm adjustable, equipped with 1000g drop weight and Φ 8mm punch, Impact depth 2mm, can accurately determine the material anti-Impact performance.

$ 286.00

Impact specimens with semi-spherical punches are used for energy consumption measurement to evaluate anti-Impact performance. Impact energy range is 3J, Impact speed is 2.5m/s, and it is suitable for a variety of film and paper tests.

$ 1348.00

Impact height 0-50cm adjustable, equipped with 1000g drop weight and Φ 8mm punch, Impact depth 2mm, can accurately determine the material resistance to Impact performance.

$ 228.00

Impact height of 120 cm, Impact depth of 2.5 mm, using a fixed mass weight to avoid secondary rebound, to ensure accurate and reliable test results.

$ 364.00

Using 1kg weight free fall impact, impact height adjustable range 0-50cm, equipped with φ 8mm punch and φ 15mm die base, can carry out positive and negative impact test.

$ 164.00

Impact height 0-100cm adjustable, Division 1cm, drop weight mass 1000g, punch diaMeter Φ 8mm, using aluminum tube material, easy to operate, Test accuracy.

$ 264.00

Impact height 120 cm, drop weight mass 1000 grams, punch diaMeter 8 mm, Impact depth 2 mm, no secondary rebound, in line with a number of national standards.

$ 348.00

Impact height 0~ 50cm adjustable, drop weight mass 1000g, the structure is simple and easy to operate, punch diaMeter 8mm and die base aperture 15mm cooperate to prevent the edge of the test plate shear.

$ 259.00

Using 2000g heavy hammer and 16mm punch, Impact depth 2.5mm, no secondary rebound phenomenon, to ensure accurate and reliable test results.

$ 370.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Selection Recommendations for Paint Film Cross-Cut Testers Based on Different Adhesion Testing Requirements
This article mainly discusses how to choose the appropriate paint film cross-cut tester based on different adhesion testing requirements.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.