Spherical SpectroPhotoMeter

An integrating sphere spectrophotometer utilizes the principle of diffuse reflection on the inner wall of the sphere to uniformly collect the reflected or transmitted light from a sample and analyze the spectrum through a spectroscopic system. It is used to measure the color, opacity, and light transmittance of materials such as coatings and plastics, and to control color consistency in the printing and papermaking industries.
Selection
When selecting an integrating sphere spectrophotometer, consider matching the measurement aperture to the sample size, ensuring the spectral range covers application requirements, meeting detection standards for instrument repeatability, having user-friendly supporting software, and ensuring maintenance costs align with the budget.

Terms

Standards

Instruments

The eccentric spherical shaft structure is used to ensure uniform mixing, and the 2800RPM speed is fixed to achieve fast vortex mixing. The TPU material countertop is wear-resistant and corrosion-resistant, and the Protection Rating reaches IP21, which is suitable for long-term stable operation.

$ 170.00

Equipped with spherical 2.5mm Φ indenter and convertible Probe, suitable for different diaMeter bobbin measurement, accuracy up to +/- 1H, supports average calculation and MAX Maximum latching, and uses USB or Bluetooth output data.

$ 489.00

The eccentric spherical shaft structure ensures uniform mixing, the fixed Rotation speed is 2800rpm to provide stable oscillation, the TPU material table is resistant to corrosion and wear, supports two operating Modes of pointing and continuous, and the volume is small and the noise is low.

$ 223.00

The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.

$ 114.00

Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.

$ 101.00

The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.

$ 106.00

Side rocker lift design to ensure smooth operation, the lifting process can be retracted and continue; with 0.01mm height display indexing, accuracy of 0.05mm, no need for each boot zero, no conductive requirements for the test plate.

$ 1445.00

The support ring contains 12 different models, covering the R10 to infinity surface range, suitable for inner and outer cylindrical and spherical surface measurement, ensuring the accuracy and Stability of surface hardness testing.

$ 251.00

Rotation speed 2800RPM, eccentric spherical shaft design and TPU wear-resistant table, support point and continuous blending mode, small size and low noise, suitable for liquid, liquid-solid and powder rapid and uniform mixing.

$ 223.00

Fixed speed 2800RPM, eccentric spherical shaft design to ensure uniform mixing; TPU material work surface wear-resistant and corrosion-resistant, suitable for a variety of testtube specifications; compact size and low power consumption, suitable for long-term high-speed work.

$ 177.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, the passband is narrow, and the Sensitivity is high; the five elements can be combined with any combination of direct reading measurement at the same time, the Response Time is less than 8 seconds, and the relative change of Stability in 15 seconds does not exceed 2%.

$ 2655.00

Key parameters include inter-instrument agreement ΔE*ab ≤ 0.25 and chromaticity value repeatability ΔE*ab ≤ 0.02, with features such as automatic aperture recognition, high-definition camera positioning, a damping handle, and four UV measurement modes.

$ 6334.00

Single beam of light grating system, Wavelength range 340~ 1000nm, Light spectrum Bandwidth 4nm, sealing grating monochromator design to improve Stability and Metering accuracy, automatic adjustment 0% and 100% function to simplify operation.

$ 270.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, Sensitivity is high; Five elements can be combined with any combination of direct reading measurement at the same time, flexible and convenient; Internal standard channel can correct the signal to ensure stable and reliable performance.

$ 2171.00

Using 1200L/mm grating and C-T monochromator structure, Light spectrum Bandwidth 4nm, Wavelength range 330~ 1000nm, High Linear and Stability, Support a variety of Measurement modes.

$ 364.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of UV Spectrophotometer in the Determination of Lignin in Pulp
This article introduces the application of ultraviolet spectrophotometry in determining the lignin content in pulp. Lignin is a key component affecting pulp quality. This method utilizes the characteristic absorption of lignin under ultraviolet light for measurement, offering simple and rapid operation.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Guide to Avoiding Pitfalls When Purchasing a Spectrophotometer
When selecting a spectrophotometer, it is essential to first understand its working principle based on the Lambert-Beer law, as this helps in assessing the rationality of the instrument's design.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.