Infrared Layer Thickness Meter

The infrared film thickness gauge works by irradiating the sample with infrared light and measuring the absorption of specific wavelengths of infrared light by the film. The thickness is calculated based on the correlation between absorption intensity and film thickness. It is used for detecting the thickness of coatings, plastics, and other films, and is suitable for rapid on-site measurements in production environments.
Selection
When selecting, consider the measurement range to cover the sample thickness, ensure the substrate type matches the instrument calibration curve, choose a probe size suitable for the detection location, ensure the environmental protection rating meets workshop conditions, and use matching standard samples to guarantee calibration accuracy.

Terms

Standards

Instruments

32 infrared halogen heaters, temperature range RT + 5~ 350 ℃, can be set parabolic layer or rising slope, the maximum test plate size 570mm, support the intRoduction layer Linear dispersion simulation pRoduction process.

$ 108363.00

The device can precisely control the film thickness of the ink layer of the color strip, and the ink injection amount is 0.0012g, which is used for ink contrast and color concentration detection.

$ 173.00

The device can precisely control the thickness of the ink layer, the minimum Basis Weight unit is 0.0012CC, and the compact size is φ 20 * 180mm, which is convenient for inks comparison and color concentration detection.

$ 396.00

Precise control of ink layer thickness, the minimum Basis Weight unit is 0.01CC, and the usage of Spot Color inks is predicted by calculation, which is suitable for ink contrast and color concentration detection.

$ 332.00

Measurement range 0-12mm, Accuracy of 1-3%, Support automatic identification of matrix material and continuous Measurement mode, suitable for pipeline anticorrosive layer defect location.

$ 696.00

Using high-speed ADC data collection, resolution up to 1μm, can simultaneously measure the thickness of multi-layer coatings or coatings plus substrates, with gain automatic switching and estimated thickness setting function, Measurement range 13~ 1000μm (epoxy resin coating).

$ 1132.00

Impact energy 3N, Impact device mass 75g, suitable for measurement of small or thin specimens and surface hardening layer, the minimum thickness can be measured 1mm and the minimum hardening layer depth 0.2mm.

$ 764.00

Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.

$ 149.00

Using electromagnetic induction principle to achieve nondestructive detection, measurement range of 0-9500μm, accuracy +/- 3%. With continuous single double measurement mode, automatic identification of substrate material, support 2000 sets of data storage and four statistical functions.

$ 344.00

Frequency 5.0MHz, support paint layer detection and emission to echo mode, Measurement range 2~ 160mm, suitable for a variety of workpiece thickness measurement.

$ 525.00

Using magnetic Induction and eddy Current dual principle, it can simultaneously measure paints and zinc layer thickness. Measurement range is 0-1500 μm, accuracy is +/- 1%, suitable for composite coating system inspection.

$ 1387.00

Using magnetic Induction principle to achieve 0-6000μm large-range measurement, the error is only +/- 3%. With continuous single double measurement mode, support four-point statistical function, large-capacity storage of 2000 sets of data, automatic identification of matrix material.

$ 323.00

Equipped with infrared CO2 sensor accuracy of 0.1%, air sleeve heating with ultraviolet sterilization function, effectively prevent foster pollution, support 4-layer shelf adjustment and intelligent program control.

$ 2972.00

Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.

$ 1622.00

Equipped with 254nm and 365nm dual-wavelength ultraviolet light sources, it supports thin-layer analysis and paper-layer analysis, can identify fluorescent substances, and is equipped with a 200 * 50mm filter.

$ 198.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.