Aluminum Pipe Surface Roughness Detector

The aluminum tube roughness tester moves by contacting the surface with a probe, measuring the contour fluctuations and converting them into electrical signals to display microscopic roughness values. It is used for quality inspection in aluminum tube production to control coating adhesion and printability.
Selection
When selecting, consider that the measurement range should cover the roughness range of the product, the probe material should be compatible with the hardness of the aluminum surface, the instrument's accuracy should meet the process tolerances, the environmental vibration-proof design should ensure data stability, and the software functionality should align with the inspection standards.

Terms

Standards

Instruments

Measurement range from 5mm, depth up to 22mm, suitable for a variety of Roughness Gauge to achieve profiled surface detection.

$ 275.00

It can measure the surface roughness of the hole with an aperture greater than 2mm, and the maximum depth is 9mm. It supports both flat and cylindrical measurement, and is suitable for a variety of special-shaped surface detection needs.

$ 425.00

Measurement range 0~ 500μm, stylus angle 60 degrees, can measure more than 50 readings per minute, with built-in temperature compensation and aluminum oxide wear surface design, in line with ASTM D4417 and other international standards.

$ 1437.00

DSP chip control, Measurement speed and low power consumption; Support 160μm large-range measurement, up to 320μm; Multi-ParaMeter measurement function, compatible with ISO, DIN, ANSI, JIS multiple national standards.

$ 1364.00

It can measure planar and cylindrical surface roughness, with a minimum diaMeter of 5mm and a maximum depth of 22mm, and supports a variety of Sensors to adapt to different workpiece shapes.

$ 332.00

It can be extended by 50mm, and up to 2 pieces can be installed to achieve 100mm deep hole measurement; it is suitable for deep hole internal surface roughness detection, and needs to cooperate with the measurement platform to ensure Stability.

$ 157.00

Built-in stylus design Measurement range 0~ 500 microns, can measure more than 50 readings per minute, equipped with tungsten carbide tip and aluminum oxide wear surface, with temperature compensation function and meet many international standards.

$ 917.00

Microcrystalline Pottery and porcelain plate surface corrosion resistance and easy to clean, aluminum alloy shell integrated molding, speed range 0-1250rpm stepless speed, Max.stirring Capacity 3L, ND servo motor drive output power 9W.

$ 251.00

High-speed DSP processor is used to improve Measurement speed, support Ra0.05-10.0 μ m Measurement range, Sensor host integrated design is convenient for field use, and can measure the cone surface and groove of the outer circle.

$ 1145.00

Equipped with dual probes for simultaneous measurement of asperity and Coating thickness, Measurement range 3.4mm, minimum scale 1μm, support corrosion pit depth detection, in line with international standards such as ISO 2808.

$ 997.00

Adopt replica tape method to measure surface roughness, Peak Measurement range 20~ 115μm, accuracy +/- 5μm, with automatic subtracting substrate function, High Protection Rating, anti-solvent and water dust.

$ 935.00

The split structure can measure pipes with an inner diaMeter greater than 40mm, equipped with a 3.5-inch color Touchscreen, supports a Ra Measurement range of 0.005-32μm, and has Bluetooth interconnection and various Linear dispersion analysis functions.

$ 1050.00

Probe surface with wear-resistant aluminum alloy, braided cable to adapt to high temperature rough surface, resolution up to 0.1 μm, support split remote measurement, can store 2500 readings.

$ 448.00

Aluminum block Bathroom heat transfer uniform heating, temperature control accuracy +/- 0.5 ℃, gas flow rate 0-15L/min adjustable, blow pipe independent to avoid cross-contamination, to achieve rapid oxygen-free condensing.

$ 498.00

High Accuracy Inductance Sensor with Diamond stylus, Measurement accuracy is not more than +/- 10%, supports RC, GAUSS and other four filtering methods, built-in lithium battery can store 7 sets of data.

$ 1092.00

Articles

Roughness Measurement Instrument Selection: Contact vs. Non-Contact
This article introduces the differences between contact and non-contact methods when selecting a roughness measuring instrument.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Contact angle measuring instrument measures the surface wettability of paper.
The contact angle goniometer evaluates wettability by measuring the contact angle of a liquid droplet on the surface of paper, based on the principle of Young's equation. The static drop method is commonly used for measurement, requiring control over sample flatness, environmental conditions, and droplet volume, while also considering the influence of surface roughness.
Surface Roughness Tester Evaluates the Impact of Substrate on Adhesion
This article primarily explores how the surface roughness of the substrate affects the adhesion of coatings or bonds.
Paper smoothness and roughness
Paper smoothness and roughness are key parameters that describe the flatness of the paper surface, and they complement each other. Smoothness refers to the extent to which the paper surface approaches an ideal plane, while roughness reflects the amplitude and frequency of surface irregularities.