Thermostatic Box Resistance Furnace

The muffle furnace generates heat through electric heating elements and maintains a stable temperature inside the chamber using insulation materials. It is used for material heat treatment, ash determination, sintering, and other laboratory heat treatment processes. In industries such as coatings and plastics, it is employed for high-temperature treatment and quality testing of samples.
Selection
When selecting, consider that the maximum temperature must cover experimental requirements, the furnace size should match the sample volume, and temperature control accuracy should meet process standards. Pay attention to heating rate and temperature uniformity, and choose the furnace material based on usage frequency. Verify power specifications and installation conditions, and determine functional configurations according to the budget.

Terms

Standards

Instruments

The maximum temperature is 1200 ° C, the Furnace volume is 16L, and the 30-segment programmable control is used to achieve precise temperature control. The safety switch of the Furnace door and the design of the corrosion resistance Furnace improve the operation safety and durability.

$ 1716.00

The maximum temperature is 1200 ℃, the Furnace volume is 2L, the microcomputer PID controller is used for precise temperature control, the door sealing design enhances Temperature uniformity, and the corrosion resistance refractory brick Furnace is durable.

$ 838.00

The maximum temperature is 1000 ℃, the Furnace volume is 30L, the 30-segment programmable controller is used to realize automatic operation, the Furnace door sealing is good to ensure Temperature uniformity, the refractory brick Furnace and the resistance wire heating element are resistant to high temperature and have a long life.

$ 1815.00

Maximum temperature up to 1200 ℃, temperature control accuracy 1 ℃, with 30 program settings and over-temperature protection function, full range programmable automatic control of heating thermostatic, Furnace size 400 * 250 * 160mm.

$ 1272.00

The maximum temperature can reach 1200 ℃, Furnace volume 7L, using microcomputer PID controller precise temperature control, refractory brick Furnace durable, Furnace door sealing design to enhance Temperature uniformity, safe and simple operation.

$ 1145.00

With two-way door design to effectively prevent hot gas leakage, 30-stage multi-stage programmable control to achieve accurate temperature control cycle, Furnace Temperature uniformity and corrosion resistance, the maximum temperature 1200 ℃ Power 2.5KW.

$ 1046.00

With 30-stage programmable control function, the maximum temperature is 1000 ℃, the Furnace volume is 2L, the refractory brick Furnace and stainless steel material are used, and the heat loss is small and the Temperature uniformity is good.

$ 927.00

The maximum temperature is 1000 ° C and the temperature control accuracy is 1 ° C. The upper and lower left and right 4-sided heating method is used to ensure the uniform temperature in the Furnace. It is equipped with 30-stage program settings and two-stage over-temperature protection devices to support automatic control of temperature rise thermostatic.

$ 1146.00

The highest temperature up to 1000 ℃, Furnace volume 16L, the use of refractory brick Furnace and wirecoil for heater heating, with automatic safety switch and overheating and overpressure protection, Furnace door sealing good heat loss is small.

$ 1145.00

With 30 programmable control function, the maximum temperature can reach 1000 ℃, Furnace volume 7L, automatic power-off protection when opening the door, good sealing of the Furnace door and small heat loss.

$ 1046.00

The refractory brick Furnace has excellent thermal insulation performance, is equipped with 50-stage program temperature control system, Temperature Fluctuation +/- 2 ℃, supports over-temperature alarm and timing function, and the Furnace volume is 7.2L to ensure the safety and stability of the experiment.

$ 1009.00

With 30 programmable control function, support heating or stay setting, stainless steel Furnace door and microcomputer PID controller, to ensure accurate and reliable temperature control, Furnace Temperature uniformity.

$ 1313.00

Maximum temperature up to 1200 ℃, Furnace volume 16L, microcomputer PID control to ensure accurate and stable temperature, unique Furnace door design to enhance sealing to reduce heat loss, refractory brick Furnace and nickel-chrome wire heating elements to provide long-term durability.

$ 1460.00

Adopt industrial PID self-tuning temperature control technology, Temperature Fluctuation +/- 2 ℃, display accuracy 1 ℃. Up, down, left and right 4-sided heating structure, Furnace volume 30L, with over-temperature protection and automatic timing function.

$ 751.00

Adopt industrial PID self-tuning control technology, temperature control accuracy +/- 2 ℃, the highest temperature up to 1000 ℃, with over-temperature protection and automatic thermostatic Timing function, Furnace volume 7L, heating uniform and stable.

$ 412.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.