Total Chlorine Tester

The total residual chlorine tester detects chlorine content in water through chemical colorimetric reactions, measuring residual chlorine concentrations using either colorimetric or electrode methods. It is used for water quality monitoring in drinking water, swimming pool water, and industrial circulating water to ensure disinfection effectiveness meets standards.
Selection
When selecting, consider that the measurement range covers the usage requirements, the accuracy meets the testing standards, and the ease of operation fits the usage environment. Ensure that instrument calibration and maintenance are convenient, consumables are easily accessible, and the protection rating matches the on-site conditions.

Terms

Standards

Instruments

Measurement range covers 0~ 5mg/L residual chlorine total chlorine and 0~ 10mg/L chlorine dioxide, support 100 measurements, suitable for water quality testing, easy and fast operation.

$ 128.00

Simultaneous measurement of residual chlorine, chlorine dioxide, total chlorine and other five paraMeters, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and high Reliability integrated circuit to ensure long-term stable work.

$ 622.00

Simultaneous measurement of turbidity, residual chlorine and total chlorine with EPA custom Illuminant, USEPA 180.1 compliant, automatic range conversion, turbidity Measurement range from 0.00 to 4000 NTU, support for multi-unit display and GLP data management.

$ 3878.00

8Nm Narrowband Interference filter and LED Illuminant, wavelength accuracy +/- 1nm, support residual chlorine and total chlorine 0.00-5 mg/L Measurement range, built-in reaction Timer and 50 sets of Data storage, with IP67 waterproof performance.

$ 632.00

Measurement range 0~ 5mg/L, can carry out 100 measurements, suitable for a variety of water quality analysis instruments, easy to operate quickly detect residual chlorine and total chlorine content.

$ 122.00

With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.

$ 2505.00

LED Illuminant provides stable detection performance, supports CAL CheckTM calibrated verification, Measurement range 0-500ppb, accuracy +/- 5ppb, with reference to USEPA method 330.5 and DPD method for ultra-low concentration total chlorine detection.

$ 215.00

The DPD method reacts with chlorine to pRoduce a pink color. Measurement range is 0.00 to 5.00 mg/L, providing 100 tests to ensure fast and accurate Colorimetric analysis.

$ 151.00

Measurement accuracy is ensured by 515nm wavelength Illuminant, Measurement range 0.02-3 mg/L, support 200 sets of Data storage and IP65 protection, lithium battery power supply is convenient for field use.

$ 385.00

Optical inspection system using cold Illuminant narrowband interference, Optical inspection stability is less than 0.002A/20min, can save 20 standard Linear dispersion and 199 measured values, IP65 protection design to adapt to the field environment.

$ 499.00

Measurement range of 0.00 to 5.00 mg/L, accuracy +/- 0.03 mg/L, built-in reaction Timer and Automatic calibration verification function to ensure measurement conformity.

$ 632.00

Using imported cold light source and TMB photometry, the detection limit reaches 0.1mg/L, supports continuous measurement and standard Measurement mode, built-in 4000 data storage and a variety of transmission interfaces.

$ 816.00

Measurement accuracy is ensured by 515nm LED Illuminant, intelligent end point determination supports automatic reading, IP65 Protection Rating adapts to a variety of environments, and built-in 200 sets of Data storage meet detection needs.

$ 582.00

Using 515nm and 420nm dual LED Illuminant, equipped with high definition color LCD screen, built-in multiple Measuring methods, support automatic reading and Data storage functions, IP65 Protection Rating to ensure outdoor use Reliability.

$ 635.00

Using BNC connector design, equipped with 60mL calibrated solution and residual chlorine regulator, replaceable membrane to extend service life, suitable for water quality monitoring.

$ 309.00

Articles

Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Haze meter measures light transmission and scattering in agricultural film.
This article introduces how a haze meter measures the light transmittance and the proportion of scattered light in agricultural films. Haze is the percentage of scattered light in the total transmitted light, while light transmittance is the ratio of transmitted light to incident light.
Summary of Balance Selection for Different Application Scenarios
This article discusses how to choose a balance based on usage needs. First, you need to understand the basic parameters of a balance, such as its maximum capacity and precision.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.
Wire rod Applicator: Principles, Applications, and Selection Guide - A Precision Coating Tool
This article provides a detailed introduction to the working principles of a Wire rod Applicator, including the mechanism by which it controls wet film thickness through the gap between stainless steel wires. It elaborates on its wide range of applications in fields such as coatings, inks, and lithium batteries, and summarizes its technical advantages, including precise control and ease of operation.