Horizontal Vibrating Centrifuge

The horizontal vibrating centrifuge generates excitation force through the motor-driven eccentric block, causing the horizontally installed screen basket to rotate while vibrating. Under the combined action of centrifugal force and vibration, the material achieves solid-liquid separation, with the screen intercepting solids and the liquid passing through the filter. It is used for applications such as pigment dehydration in the coatings industry, pulp screening in papermaking, and plastic particle classification.
Selection
Selection must match material characteristics with screen aperture, and determine sieve basket size based on processing capacity. Motor power must meet load requirements, and vibration parameters should be adapted to material separation needs. Consider corrosion-resistant materials for chemical environments, as structural design affects maintenance convenience. Energy consumption and operating costs require comprehensive evaluation.

Terms

Standards

Instruments

Horizontal Vibration Technology, Vibration Frequency 45-200Hz Adjustable, Throwing plate diaMeter 300mm, can handle multiple samples and automatically complete the polishing process.

$ 5834.00

Double-sided horizontal mounting design can accommodate 40 5ml centrifuge tubes, suitable for standard centrifuge tube specifications, improving Sample Handling efficiency and ease of operation.

$ 149.00

Screening area of 54200m ², Vibration Frequency 400-3000 times/min adjustable, amplitude 3.2 +/- 0.1mm, compact size easy to operate, screen plate easy to disassemble, optional different gap specifications to adapt to a variety of Stocks.

$ 4592.00

Using U-tube oscillation principle, density resolution of 0.0001g/cm ³, built-in injection pump and video camera function, automatic cleaning and drying, support concentration conversion and a variety of output methods.

$ 6213.00

Using U-tube oscillation principle, with Peltier precise temperature control technology, density resolution of 0.0001g/cm ³, built-in injection pump and drying air pump, automatic injection, cleaning and drying, high-resolution video direct observation of samples to avoid bubble influence.

$ 4227.00

Measurement accuracy of 0.001g/cm ³, built-in automatic sampling pump and high-resolution video observation function, support for Peltier temperature control technology, ensure accurate and reliable test results.

$ 3399.00

The double-sided horizontal mounting design can simultaneously accommodate 16 50ml centrifuge tubes, which are suitable for standard 50ml tube specifications and provide a stable and reliable sample carrying platform.

$ 149.00

Using U-tube oscillation principle, density resolution of 0.0001g/cm ³, built-in injection pump and video camera, automatic cleaning and drying, support concentration conversion and a variety of Data output methods.

$ 5468.00

Using U-tube oscillation principle, density resolution of 0.0001g/cm ³, repeatability error of 0.0006g/cm ³, built-in injection pump and video camera, automatic cleaning and drying, support concentration conversion and a variety of data output.

$ 4848.00

The 6-well design supports 15ml capacity Sample Handling, which is suitable for a variety of Centrifuge models and provides stable centrifugal separation results.

$ 127.00

With 3000 times/min and 6000 times/min two vibration frequencies, the amplitude can be continuously adjusted between 0mm and 3mm, supporting three modes of subtle vibration, intermittent vibration and continuous vibration, suitable for ≤ 325 mesh material analysis.

$ 811.00

Double-sided horizontal mounting design can accommodate 40 centrifuge tubes simultaneously, compatible with 1.5ml and 2.0ml specifications, suitable for swirl/spin Mixer for efficient Sample Handling.

$ 149.00

With two movements of reciprocating and top-beating vibration, the screening efficiency is high and does not block the screen surface. It can be adapted to a set of screening screens of Φ 200, Φ 75, and Φ 100. The number of swirl/spins is 290 +/- 6 times/minute, and the number of beats is 156 +/- 3 times.

$ 1763.00

It is designed with 24-hole 0.5ml specification, suitable for a variety of Centrifuge models, with high temperature resistance and high voltage characteristics and excellent chemical Stability.

$ 127.00

Support 100 ℃ high temperature heating, suitable for 24 holes 5ml centrifuge tube, optional electronic ice box and thermostatic metal Bath module, achieve precise temperature control and diverse Sample Handling.

$ 175.00

Articles

Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Vibration test bench simulates transport packaging environment testing.
Vibration testing tables simulate the vibration environment during transportation in the laboratory to test packaging and evaluate its protective performance. The tests primarily follow domestic and international standards, simulating sinusoidal or random vibrations that cover typical transportation conditions such as road and rail.
The impact of temperature, humidity, and vibration coupling in a three-environmental test chamber on the structural fatigue of products.
This article explores the impact of the coupled effects of temperature, humidity, and vibration in a three-comprehensive test chamber on the structural fatigue of products. It explains how such a coupled environment accelerates the degradation of material performance, such as high temperature and humidity reducing the material's fatigue limit, while vibration promotes crack propagation.
Performance Comparison and Selection Guide Between Electric Vibration Tables and Hydraulic Vibration Tables
Electric shakers and hydraulic shakers are two commonly used vibration testing devices, each with different working principles. When selecting a model, factors such as test frequency, specimen weight, displacement requirements, and cost need to be considered.
Selection Differences Between Random Vibration and Sine Vibration Tests
This article primarily discusses the differences between random vibration and sinusoidal vibration tests. Sinusoidal vibration uses a periodic signal at a single frequency, making it suitable for identifying resonance points and conducting fatigue tests. Random vibration, on the other hand, employs a broadband random signal to simulate real-world environments, such as transportation jolts, making it more appropriate for reliability acceptance testing.
Key points for selecting a multi-factor comprehensive test chamber with integrated temperature, humidity, vibration, and altitude systems
The multi-factor comprehensive test chamber integrates four environmental stresses: temperature, humidity, vibration, and altitude (low pressure), used to simulate the reliability of products under complex environmental conditions.
Selection Guide How to Choose a Vibration Test Bench Based on Testing Standards
When selecting a vibration test system, start by carefully reviewing the test standards to clarify key parameters such as frequency range, thrust force, displacement, acceleration, and vibration type. Then, based on the standard requirements, calculate the required thrust force, match the specifications of the shaker and amplifier, and select an appropriate control system.
For electromagnetic vibration tables, whether to choose sweep frequency or fixed frequency testing standards for simulating transportation is crucial; do not make a random selection if you are unsure.
The electromagnetic vibration table is used to simulate transportation vibrations and test the durability of products and packaging. There are two types of tests: fixed-frequency and sweep-frequency. The selection should be based on the test objectives and relevant standards to avoid arbitrary choices. For new products, it is recommended to first conduct a sweep-frequency test to identify resonance points, followed by fixed-frequency tests as needed.