Controlled by single chip microcomputer, temperature accuracy +/- 0.03 ℃, kinematic viscosity measurement range 0.5~ 20000mm ²/s, automatic tracking of heating Linear dispersion and precise control of water Bath and oil Bath temperature.
Using 10L Glass Bathtub, small size and less medium consumption, temperature control accuracy of +/- 0.05 ℃, automatic accurate timing and viscosity calculation, support 4 holes at the same time experiment, easy and reliable operation.
Adapted diaMeter 16mm formed Metering Rod, the total length of 2000mm, through the special structure to correct the straightness of the Rod body, to ensure stable rotation and full contact with the substrate, improve the thickness control accuracy of Spreader.
Using Metering Rod & doctor blade double Spreader mode, Spreader accuracy up to +/- 0.001mm, Spreader rate 5~ 200mm/s adjustable, fixed substrate by vacuum adsorption to ensure film uniformity and repRoducibility.
Spreader speed 5~ 180mm/s, Spreader area 400 * 300mm, using Metering Rod & doctor blade and vacuum adsorption system to ensure Spreader uniformity and Stability, can be customized automatic inking function.
Ubbelohde DIN standard design, viscosity measurement range of 100-500cSt, based on the principle of capillary tubing flow time proportional to viscosity, to ensure accurate determination of liquid kinematic viscosity.
Using Metering Rod & doctor blade dual Spreader method, Spreader accuracy is up to +/- 10μm, Film thickness range is 0-5000μm. Spreader rate and stroke are controlled by vacuum adsorption to fix the substrate, and the touch screen can effectively improve film repRoducibility and conformity.
The instrument adopts Precision Platinum Resistance Sensor with temperature control accuracy of +/- 0.1 ℃ and kinematic viscosity measurement range of 0~ 10000mm ²/S, which is suitable for viscosity analysis of various liquids under thermostatic conditions.
Applicable to the flow time of not less than 20 seconds viscosity measurement, using aluminum material, capacity 50ml, flow hole diaMeter 5.6mm, can be converted into kinematic viscosity.
Using Cannon-Fenske opaque design, suitable for opaque liquid measurement, viscosity measurement range of 240~ 1200cSt, High Accuracy viscosity detection based on capillary tubing outflow time method.
Ubbelohde ASTM standard design, viscosity measurement range of 20-100cSt, based on the principle of capillary tubing can accurately determine the kinematic viscosity of liquids, suitable for a variety of fluid analysis.
Ubbelohde DIN standard design, viscosity measurement range of 0.35~ 1cSt, based on the principle of capillary tubing flow time proportional to viscosity, to ensure High Accuracy and Repeatability.
Using PID intelligent temperature control technology, Precision temperature control up to +/- 0.1 ℃, equipped with 7-inch Touchscreen and four-hole test position, automatically calculate viscosity and store 50 sets of data, easy and efficient operation.
U-shaped tube design, viscosity measurement range of 60-300cSt, based on the principle of capillary tubing to achieve accurate measurement of liquid kinematic viscosity and outflow time.
Ubbelohde ASTM standard design, viscosity measurement range of 1~ 5cSt, based on the principle of capillary tubing liquid flow time is proportional to viscosity, suitable for accurate determination of a variety of liquid samples.