Water Hardness Rapid Tester

The water hardness rapid tester is based on the principle of complexometric titration. It utilizes EDTA reagent to react with calcium and magnesium ions, producing a color change, and employs a photoelectric sensor to measure the colorimetric variation, which is then converted into hardness values. It is used for on-site rapid detection of calcium and magnesium ion concentrations in industrial water and circulating cooling water, enabling monitoring of scaling tendencies.
Selection
When selecting, focus on ensuring the detection range covers the application scenarios, the accuracy meets process requirements, and the operation interface is simple and easy to read. Verify the instrument's calibration cycle and the stability of consumables supply, ensure the protection level is suitable for the usage environment, and configure data storage functions as needed.

Terms

Standards

Instruments

Imported special steel pressure needle, Hardness and long life, range 0-20HW, can directly read the Hardness value, suitable for on-site rapid testing, Stability and portability.

$ 1017.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, Measurement accuracy +/- 1% F.S., can store 1000 sets of data, suitable for a variety of Ion concentration and water Hardness detection.

$ 864.00

The minimum measurable inner diaMeter is 10mm, the maximum sample thickness is 6mm, and the imported special steel crimp and high-strength pointer components are used. It has good Stability and portability and supports Hardness value conversion.

$ 1017.00

Suitable for Ammonia Gas sensing electRode maintenance, capacity 480mL, Water Hardness Detection dedicated to ensure ElectRode performance stability, prolong service life.

$ 135.00

Using mechanical compression spring design, Measurement accuracy 0.5HW, Film thickness 0.4-6 mm workpiece can be detected, and a variety of Hardness values can be obtained through the conversion table, which is suitable for on-site rapid detection.

$ 477.00

The use of New material has a long life, stable fullness point and correction point, Hardness value can be converted into Vickers Rockwell Brinell, the range is 0-20HW, and the accuracy is 0.5HW, which is suitable for workpieces with a thickness of 0.6-13 mm.

$ 725.00

New material has a long life and full point stability accuracy of 0.5HW, which can be quickly tested on site and supports a variety of Hardness value conversions, suitable for 0.6-6 mm thickness materials.

$ 633.00

New material pressure needle Hardness long life, high strength pointer is not easy to deform, forging handle wear and pollution resistance, range 0-20HW accuracy 0.5HW, can be quickly tested on site and support multi Hardness value conversion.

$ 666.00

Using LED test technology, signal stability, support multi-point calibrating and GLP specification, Measurement range Water Hardness 0.000-500.0mg/L, urea 0.000-5.000 mg/L, compact and easy to carry.

$ 541.00

Colorimetric integrated tube design, no need to transfer liquid, support more than 10 measurements to take the average value, measurement error ≤ +/- 5%, Repeatability ≤ +/- 5%, built-in two COD detection methods, can expand a variety of water quality paraMeter detection.

$ 2526.00

The three-point contact design ensures a 45-degree test angle and provides a 500/750/1000g three-speed load for rapid determination of coating Hardness and is suitable for laboratory and field environments.

$ 143.00

Measurement range 63-105HRF, suitable for Film thickness 0.4-6 mm workpiece, mechanical compression spring device durable and reliable, can directly read the Hardness value.

$ 461.00

New material pressure needle Hardness high life, high strength pointer is not easy to deform, forging handle wear and pollution resistance, full point and correction point stability, accuracy 0.5HW, suitable for 0.6-13 mm thickness samples.

$ 540.00

New material pressure needle Hardness high life, high strength pointer is not easy to deform, forging handle wear and pollution resistance, full point and correction point stability, accuracy 0.5HW, suitable for 0.6-6 mm thickness material.

$ 451.00

Measurable Film thickness 0.4-8 mm, accuracy 0.5HW, mechanical compression spring design durable, high toughness table glass anti-Impact, support a variety of Hardness value conversion, suitable for soft metals such as aluminum alloy.

$ 477.00

Articles

Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Cross-cut tester combined with adhesion test tape for evaluating coating peel-off.
The cross-cut test, paired with adhesion test tape, is a commonly used method for evaluating coating adhesion. It involves using a cross-cut knife to score a grid pattern on the coating surface, followed by the rapid peeling of specialized tape. The adhesion level is then assessed by observing the extent of coating detachment.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.