Fixed-position Vortex Mixer

The fixed mixer uses a motor to drive the sample container in circular or reciprocating motion, creating vortices within the liquid to achieve mixing. It is used for solution mixing, dissolution, or emulsification operations during laboratory sample preparation, commonly found in biochemical testing and material preparation processes.
Selection
When selecting, consider the sample viscosity to match the speed range, confirm fixture compatibility based on container dimensions, choose a heating module if temperature control is needed, select mechanical structure durability according to usage frequency, and pay attention to the impact of operational noise on the experimental environment.

Terms

Instruments

The eccentric spherical shaft design ensures uniform mixing, and the fixed speed of 2800RPM realizes fast vortex mixing. The TPU material countertop is wear-resistant and corrosion-resistant, small in size and low in noise.

$ 190.00

The eccentric spherical shaft structure is used to ensure uniform mixing, and the 2800RPM speed is fixed to achieve fast vortex mixing. The TPU material countertop is wear-resistant and corrosion-resistant, and the Protection Rating reaches IP21, which is suitable for long-term stable operation.

$ 170.00

The eccentric spherical shaft design ensures uniform mixing, the fixed Rotation speed is 2800RPM to achieve fast vortex mixing, the TPU material work surface is wear-resistant and corrosion-resistant, the structure is compact, the noise is low, and the power consumption is only 60W.

$ 223.00

Fixed Rotation speed 2800RPM, eccentric spherical shaft design for easy installation of vibration head, reinforced engineering plastics and TPU table, acid and alkali wear resistance, support point and continuous Operating Mode.

$ 189.00

Rotation speed 2500rpm, can handle 2000ml volume sample, integrated magnetic stirring, vortex mixing and microplate oscillation multi-function.

$ 396.00

Fixed Rotation speed 2800RPM, eccentric spherical shaft design for easy installation of vibration head, using TPU work surface corrosion resistance and wear resistance, small size, low power consumption and low noise, suitable for high-speed mixing of liquid-liquid, liquid-solid, solid-solid samples.

$ 223.00

Rotation speed of 2800RPM is fixed to ensure efficient mixing, TPU material work surface is wear-resistant and corrosion-resistant, with two operating Modes of pointing and continuous to meet different experimental needs.

$ 223.00

Two Operating Modes, point and continuous, fixed speed up to 3000rpm, track diaMeter 4mm, compact and lightweight only 3.5kg, engineering plastic shell corrosion resistance, stable operation.

$ 141.00

Fixed speed 2800RPM, eccentric spherical shaft design to ensure uniform mixing; TPU material work surface wear-resistant and corrosion-resistant, suitable for a variety of testtube specifications; compact size and low power consumption, suitable for long-term high-speed work.

$ 177.00

The eccentric spherical shaft structure ensures uniform mixing, the fixed Rotation speed is 2800rpm to provide stable oscillation, the TPU material table is resistant to corrosion and wear, supports two operating Modes of pointing and continuous, and the volume is small and the noise is low.

$ 223.00

Rotation speed 2800RPM, eccentric spherical shaft design and TPU wear-resistant table, support point and continuous blending mode, small size and low noise, suitable for liquid, liquid-solid and powder rapid and uniform mixing.

$ 223.00

With magnetic stirring function, the maximum stirring capacity of 2000ml, Speed range 200-2500rpm, vibration range 4.5mm, support point and continuous operation mode switching.

$ 359.00

High frequency vibration vortex to achieve uniform mixing, speed range 0-2800rpm, support point and continuous operation mode, no need to add magnetic components to avoid sample contamination, suitable for rapid mixing of various containers.

$ 183.00

With point and continuous operation mode, Speed range 200-2500rpm, reinforced engineering plastics and TPU work surface, acid and alkali wear resistance, support magnetic stirring and microplate adaptation.

$ 378.00

The DC motor is not easy to heat up and can run for a long time, the speed range is 100~ 2800rpm, with two operation modes of light induction and continuous, and supports 1~ 99h59m59s timing function.

$ 254.00

Articles

Optimization of mixing efficiency of vortex mixer in liquid-liquid microextraction
This paper explores how to enhance mixing efficiency in liquid-liquid microextraction by adjusting the operating parameters of a vortex mixer.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Heat Deflection Temperature Tester for Measuring the Thermal Resistance of Carbon Fiber Reinforced Plastics
This article introduces the method of testing the heat resistance of carbon fiber-reinforced plastics using a heat deflection temperature tester. The instrument applies a fixed load to the material while increasing the temperature, measuring the temperature at which the material reaches a specified deformation, thereby evaluating its short-term resistance to thermal deformation.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Heat Sealing Tester Determines the Optimal Heat Sealing Temperature for Films
A heat seal tester is used to determine the optimal heat sealing temperature of films to ensure the sealing strength and integrity of packaging. During testing, by setting a temperature gradient and fixing parameters such as pressure and time, samples are heat-sealed at different temperatures, and then their strength is measured.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Circle Method Adhesion Tester for Evaluating the Adhesion of Paint Coatings by the Circular Rolling Line Method
The rolling circle method is a technique for testing the adhesion of paint coatings using a circle-drawing instrument. The instrument employs a fixed-load stylus to draw a continuous circular trace on the coating at a constant speed, and the adhesion level is assessed based on the peeling condition of the scratch.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Operation Specification for Circular Scratch Adhesion Tester
The circle method adhesion tester is used to evaluate the adhesion strength between coatings and substrates. Before operation, it is necessary to inspect the instrument, prepare samples, and control the ambient temperature and humidity. During testing, the sample should be secured, appropriate load and scratch spacing should be selected, and the stylus should be moved at a constant speed to create a circular scratch.
Stormer viscometer measures the KU viscosity of latex paint
This article introduces the method of measuring the KU viscosity of latex paint using a Stormer viscometer. The viscometer measures the load required to maintain a fixed rotational speed through the rotation of its paddle, thereby calculating the KU value, which is related to the application and storage properties of the coating.