Electrolytic Water Content Analyzer

The electrolytic moisture analyzer utilizes a phosphorus pentoxide film within the electrolytic cell to absorb moisture from the sample gas. The absorbed moisture is then electrolyzed to produce hydrogen and oxygen, and the moisture content is calculated by measuring the electrolysis current. This instrument is used for detecting trace moisture in gases, liquids, and solids, and finds applications in gas purity testing and process control in industries such as chemical, electronics, and power.
Selection
When selecting an electrolytic moisture analyzer, considerations should include the measurement range covering the moisture content of the sample, precision meeting detection requirements, response time suiting the detection frequency, the lifespan of the electrolytic cell affecting maintenance costs, operational compatibility with temperature and humidity conditions, instrument dimensions matching the available space, and referencing real-world application cases to validate suitability.

Terms

Standards

Instruments

Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.

$ 1397.00

4 groups of samples can be tested at the same time, using PID precise temperature control technology, Temperature range from room temperature to 1000 ℃, with automatic calculation of carbon black content and ash content function, open lid structure heat dissipation effect is better.

$ 6205.00

With manual and automatic temperature compensation function, Measurement range 0-6 PCL, resolution up to 0.01 PCL, easy operation and intuitive and accurate digital display, suitable for a variety of water quality monitoring scenarios.

$ 382.00

Measurement range 0~ 1.5mg/L, resolution up to 0.01mg/L, eliminating human error, suitable for the determination of inorganic phosphoric acid content after digestion of various water samples.

$ 285.00

Measurement range 0.23 nm g/L to 23 g/L, temperature compensation 5~ 50 ℃, suitable for high purity water and industrial drainage sodium ion concentration determination, repeatability error does not exceed 0.03pNa.

$ 262.00

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Measurement unit with Baume degree, sugar content accuracy +/- 0.1 ° Baumé, automatic temperature compensation, 1.5 seconds fast display results, only 2 drops of sample, waterproof design for a variety of environments.

$ 567.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

4 groups of samples can be tested at the same time, using PID temperature control accuracy of 0.1 ℃, support segmented program heating, one key automatic calculation of carbon black and ash content, open the lid structure heat dissipation fast.

$ 2784.00

The thermal weight loss method is used to measure carbon black content, the operating temperature can reach 990 ° C, and the 7-inch Touchscreen is equipped to realize one-button calculation, support segmented paraMeter setting, and the Furnace body separation design has better heat dissipation.

$ 1848.00

The fat content was determined by Soxhlet extraction principle, the measurement range was 0.5% -60%, and two samples could be processed at the same time.

$ 428.00

Measurement range 0.03~ 50μm, resolution 0.01μm, support single-layer, multi-layer and alloy platings testing, built-in thermal printer to automatically output statistical reports, suitable for wire and columnar workpieces.

$ 1364.00

Measurement range 0.00-2 ppm, accuracy +/- 0.10ppm, support CAL CheckTM function verification accuracy, suitable for rapid analysis of fluoride content in drinking water.

$ 215.00

It can measure refractive index 1.3000~ 1.7000nD and sugar content 0~ 100% Brix, with accuracy of +/- 0.0002nD and +/- 0.1% Brix, respectively, and supports temperature correction and direct data printout.

$ 1282.00

Measurement range 0~ 300μm, resolution up to 0.01μm, support multi-layer nickel potential difference analysis, test size optional Φ 2.4mm to Φ 0.8mm.

$ 2978.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Moisture Analyzer Combined with Karl Fischer Method for Measuring Moisture Content in Resin Solvents.
This article introduces the use of the Karl Fischer method in conjunction with a moisture analyzer to measure the water content in resin solvents.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.
Application of Coulometric Moisture Titrator in Moisture Detection of Electronic Components
Coulometric moisture titrators operate based on the principle of electrolysis, directly calculating the moisture content in samples by measuring the electrolytic charge without the need for calibration. In the field of electronic components, moisture can lead to issues such as corrosion and reduced insulation, making its detection critically important.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.