Traffic Sign ChromaMeter

The traffic sign colorimeter captures the reflected light from the surface of road signs using optical sensors and analyzes the color data. It is used to detect the color consistency of road markings and traffic signs, ensuring compliance with safety standards. It is applied in the fields of highway maintenance and traffic facility quality inspection.
Selection
When selecting, focus on measurement accuracy and compliance with standards, considering environmental adaptability such as outdoor shock and dust resistance. Check whether it supports the color coding system of the transportation industry, and ensure that the ease of operation and data output formats meet recording requirements. Compare the maintenance costs and calibration cycles of different models.

Terms

Instruments

Observation angle 0.2 °~ 2.0 ° continuously adjustable, incident angle -40 °~ + 40 ° adjustable, using silicon diode Detector and lithium battery power supply, support continuous work for more than 30 hours, suitable for indoor and outdoor measurement.

$ 6386.00

Measurement time only 1.5 seconds, chromatic value Repeatability Delta E * ab within 0.04, support polygon tolerance master standard determination, can customize the color gamut range to meet special detection needs.

$ 4237.00

With 0.2 °~ 2.0 ° continuously adjustable observation angle and a variety of incident angle settings, Measurement range 0~ 1999 mcd • lx-1, using silicon diode Detector and standard A Illuminant, to ensure Measurement accuracy consistent with international standards.

$ 5600.00

The 2850mm sand guide tube and 850μm filtrate net are used to control the falling sand, the calibration funnel can adjust the uniformity of the sand volume, and the sample holder can freely adjust the height and horizontal direction to ensure the Test accuracy and Reliability.

$ 779.00

Provide reference and working standard types, covering signs, markings and raised road signs, with a minimum effective reflective area of 50mm * 50mm, to meet a variety of Color and structural classification requirements.

$ 975.00

The instrument's observation angle is continuously adjustable from 0.2 ° to 2.0 °, the incident angle covers +/- 0 ° to +/- 20 °, and the Measurement range is 0~ 3000 mcd • lx-1. It uses silicon diode Detectors and standard A Illuminants to ensure measurement accuracy.

$ 6386.00

The radius of the device Impact hammer is 6.4mm, the total mass is 190 +/- 2g, the structure is reasonable, the operation is simple, the applicability is wide, the Measurement accuracy is high and safe, and it meets the requirements of GB/T24725-2009 standard.

$ 779.00

With three Frequency weighting and four Measurement paraMeters, Measurement range 30-130dB, can store 30 sets of data and support USB/Bluetooth multiple output methods to meet the accurate measurement requirements of different scenarios.

$ 212.00

The 45/0 circular illumination geometry is used, and it is equipped with a dual measurement aperture of Φ 8mm and Φ 4mm. The chromatic value repeability is within Delta E * ab 0.03, and it supports the measurement of fluorescent samples and the calculation of various color difference formulas.

$ 4237.00

Adopt digital detection technology to improve Stability, support 800 sets of data storage and 6 days continuous measurement, Measurement range 30-130dB, equipped with A/C/linear frequency weighting and fast and slow time weighting gears.

$ 996.00

Adopt 45/0 ring lighting structure, equipped with Φ 2/4/8 mm custom diaMeter, chromatic value Repeatability Delta E * ab 0.05 or less, support a variety of Color difference formula and Color space measurement.

$ 2784.00

Using 45/0 geometrical optics structure, equipped with a Φ 20mm measurement aperture and concave grating spectroscopy, it can accurately measure reflectance and chroma data, with high stability and repeability, suitable for fringe or granular samples.

$ 3914.00

Adopt 45/0 ring lighting structure, equipped with 256 pixel dual array CMOS Detector, chromatic value Repeatability Delta E * ab 0.05, support a variety of measurement aperture and Color space, to meet the needs of accurate color scheme.

$ 3398.00

With three frequency weighting and four measurement modes, the measurement range is 30-130dB, the accuracy is 1dB, and the built-in 30 data storage functions support USB and Bluetooth data transmission.

$ 525.00

Using 45/0 geometrical optics structure, equipped with 256 pixel dual array CMOS Detector, chromatic value repeability Delta E * ab 0.05, supports a variety of color difference formula and Color index measurement.

$ 2784.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.