Fast Temperature Measurement Gun

The fast temperature measurement gun is based on the principle of infrared thermometry. It converts the infrared energy radiated from the surface of an object into temperature readings, enabling non-contact measurement of the object's surface temperature. It is suitable for industrial process monitoring, equipment maintenance, and material temperature inspection.
Selection
When selecting a fast temperature gun, consider the measurement temperature range, accuracy, response time, emissivity adjustment capability, environmental resistance, display clarity, and ease of operation, ensuring they match the specific application scenarios and the characteristics of the objects being measured.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

Equipped with double spray guns to achieve uniform lame plating, the lifting range of the spray gun is adjustable from 10-500mm, the integrated air filtrate adjustment system supports magnetic or vacuum panel fixing, and improves the coating test Repeatability.

$ 67560.00

With -50~ 700 ℃ wide range and +/- 2% accuracy, laser positioning ensures accurate measurement of the target, 12:1 object distance ratio supports long-distance detection, 500ms fast Response real-time data.

$ 112.00

Using refractive index measurement technology, 1.5 seconds fast display results, automatic temperature compensation to ensure accuracy, only a small sample, suitable for a variety of environments, Protection Rating IP65.

$ 567.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 200GU, Repeatability +/- 0.5GU; Lightweight and portable, Automatic calibration, fast measurement, can store 254 sets of data, support USB, RS-232 and Bluetooth output.

$ 191.00

Temperature range -50 to 300 ° C, Response Time of only 4 seconds, equipped with replaceable ultra-fast Response stainless steel penetration Probe, with CAL Check ™ Adjustment and battery error prevention system to ensure accurate and reliable measurement.

$ 309.00

Measurement range 4-40%, Accuracy +/- 0.5%, 1 second fast Response, using temperature and humidity compensation technology to ensure accuracy, Portable design weight is only 203g, suitable for on-site rapid detection.

$ 144.00

With -32~ 380 ℃ wide range and +/- 2% accuracy, 12:1 object distance ratio for non-contact measurement, 500ms Fast Response and equipped with laser positioning function.

$ 79.00

Adopt 8mm measurement diaMeter, 0.5 seconds fast measurement, repeability accuracy Delta E < 0.07, equipped with 2.8 inch color display, built-in whiteboard automatic correction, support a variety of Measurement modes and five Color Spaces.

$ 719.00

Response Time of only 4 seconds, temperature range of -50.0 to 300 ℃, equipped with replaceable ultra-fast Response K stainless steel penetration Probe, with CAL Check ™ calibrate inspection and automatic shutdown function.

$ 309.00

Fully pneumatic design ensures stable operation, adjustable spray gun settings for precise atomization and film thickness control, and magnetic panel supports multiple substrate tests.

$ 59126.00

Measurement range salinity 0.0~ 28.0%, temperature 10~ 100 ℃, resolution 0.1% Brix, only 0.3mL sample volume, 3 seconds fast results, portable design weight 100g.

$ 198.00

With a wide temperature measurement range of -50~ 480 ℃, the accuracy is +/- 1.5%, the Response Time is only 500ms, the object distance ratio is 12:1, suitable for fast non-contact measurement, lightweight and portable.

$ 103.00

Four-terminal Resistance Measuring method is used to eliminate the influence of wire resistance, test Precision 0.1% reading + 2 words, Measurement speed is fast 32 times/second, with perfect sorting function, alarm value can be set for percentage sorting, strong anti-interference ability.

$ 251.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor temperature control system, the studio is made of 304 stainless steel for fast and uniform heating.

$ 775.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.

$ 883.00

Articles

Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Cross-cut tester combined with adhesion test tape for evaluating coating peel-off.
The cross-cut test, paired with adhesion test tape, is a commonly used method for evaluating coating adhesion. It involves using a cross-cut knife to score a grid pattern on the coating surface, followed by the rapid peeling of specialized tape. The adhesion level is then assessed by observing the extent of coating detachment.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.