Low Temperature Thermostatic Reaction Bath

The low-temperature constant temperature reaction bath reduces the temperature of the liquid inside the tank through a refrigeration system, and maintains the set temperature in combination with heating elements and a temperature controller. It provides a stable low-temperature environment for chemical reactions, sample storage, and other applications, and is used in fields such as material testing and biological experiments.
Selection
When selecting, consider that the temperature range should cover experimental needs, the temperature control accuracy should match sample sensitivity, the tank capacity should accommodate sample size, and media compatibility should avoid corrosion. Ensure the cooling power meets the required cooling rate, while also paying attention to safety features and the convenience of daily maintenance.

Terms

Standards

Instruments

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Temperature range -5~ 100 ℃, temperature resolution 0.01 ℃, with overheating and overcurrent protection and self-tuning function, stainless steel 304 liner and centrifugal circulation pump to ensure stable operation.

$ 1800.00

Temperature range -30~ 100 ℃, temperature resolution up to 0.01 ℃, equipped with large screen backlight LCD display and overheating and overcurrent protection to ensure the safety and stability of the experimental process.

$ 4150.00

Temperature control accuracy of 0.01 ℃, the temperature range covers -40 to 100 ℃, the use of fully enclosed Compressor refrigeration and heat-free centrifugal circulation pump, to ensure that the temperature is stable and uniform, and has multiple overheating and overcurrent protection.

$ 2549.00

Temperature range -50~ 100 ℃, temperature resolution of 0.01 ℃, fully enclosed Compressor refrigeration and 304 stainless steel liner, equipped with 10L/min circulating pump and removable side panels for easy cleaning and maintenance.

$ 5931.00

Adopt fully enclosed Compressor refrigeration system, Temperature range -20~ 100 ℃, temperature resolution 0.01 ℃, with overheating and overcurrent protection and self-tuning function, stainless steel 304 structure is easy to clean, side plate can be flexibly disassembled and assembled.

$ 1258.00

Temperature range -5~ 100 ℃ and accuracy of 0.1 ℃, using fully enclosed Compressor refrigeration system and no heat centrifugal circulation pump, equipped with overheating and overcurrent protection and removable side plate, Tank volume 15L and pump flow 10L/min.

$ 1597.00

The double Compressor and cascade refrigeration system are used to cool down quickly and have low noise; the overall foaming insulation of the Tank body reduces the loss of cooling capacity, the flow rate of the circulating pump is 10L/min to ensure Temperature uniformity, and the Temperature Fluctuation is only +/- 0.05 ℃.

$ 1653.00

Imported PT100 temperature sensor, Temperature range -20~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, double Compressor cascade refrigeration system to ensure rapid cooling, 30L Tank overall foaming insulation to reduce cooling loss.

$ 3268.00

Double Compressor refrigeration system is adopted to ensure rapid cooling, Tank volume 6L, Pump Flow rate 8L/min to ensure liquid uniformity, Temperature Fluctuation is controlled within +/- 0.05 ℃, and the overall foaming process reduces cooling loss.

$ 946.00

The fully enclosed Compressor is used for refrigeration and overheating and overcurrent protection, the temperature control accuracy reaches 0.01 ° C, the pump flow rate is 10L/min, the stainless steel 304 structure is easy to clean, and the side plate can be disassembled for easy maintenance.

$ 5544.00

Can achieve -80 ℃ low temperature control, built-in two-stage magnetic stirring system, Speed range 100-1200RPM, equipped with high temperature and over-temperature protection functions, environmentally friendly refrigerant to ensure safe operation.

$ 4222.00

Imported Pt100 temperature sensor, Temperature range -30~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, double Compressor cascade refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.

$ 2575.00

Temperature range -30~ 100 ℃, temperature resolution 0.1 ℃, fully enclosed Compressor refrigeration and overheating overcurrent protection, stainless steel liner for easy cleaning, high performance centrifugal pump to ensure uniform temperature.

$ 1777.00

Imported Pt100 temperature sensor and dual Compressor refrigeration system, rapid cooling and low noise, Temperature Fluctuation +/- 0.05 ℃, 6L volume Tank with 8L/min circulating pump to ensure Temperature uniformity.

$ 971.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Differential Scanning Calorimetry measures the heat of curing reaction of thermosetting polymers.
Differential scanning calorimetry is a commonly used technique for studying the curing reactions of thermosetting polymers. It measures the heat released by a sample during heating to obtain key parameters such as reaction enthalpy and curing temperature.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Differential Scanning Calorimetry for Measuring the Degree of Cure of Polymer Optical Waveguide Materials
This article introduces a method for determining the degree of curing in polymer optical waveguide materials using a differential scanning calorimeter. The degree of curing is a key indicator affecting material performance, and this instrument quantitatively analyzes it by measuring the thermal effects during the curing reaction.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Differential Scanning Calorimetry Study on the Curing Reaction Kinetics of Epoxy Resin
This article introduces the method of using differential scanning calorimetry to study the curing reaction kinetics of epoxy resins.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.