Ford viscosity Cup for pigments

The Ford viscosity cup determines viscosity by measuring the time required for a fluid to flow out through a standard aperture. It is used in industries such as coatings and inks for on-site rapid detection of flow characteristics, ensuring uniformity in application and printing.
Selection
When selecting a Ford viscosity cup for pigments, consider the viscosity range of the material being tested and match it with the appropriate orifice size of the cup. Choose materials such as stainless steel or aluminum based on the usage environment. Ensure that the cup complies with standards like ASTM D1200 to facilitate result comparison.

Terms

Standards

Instruments

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Aperture 4.12mm, viscosity measurement range of 70~ 370cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Outflow aperture 1.9mm, viscosity measurement range of 10~ 35cSt, aluminum alloy Cup body and stainless steel pore structure durable, in line with ASTM D1200 standard.

$ 167.00

Using stainless steel aperture 5.20mm, viscosity measurement range of 200~ 1200cSt, aluminum alloy Cup body sturdy and durable, in line with ASTM D1200 standard, suitable for laboratory accurate measurement of fluid viscosity.

$ 170.00

Measurement range of 25~ 120cSt, outflow aperture of 2.53mm, suitable for laboratory viscosity testing.

$ 167.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, aperture 1.90mm, viscosity measurement range of 10~ 35cSt, flow time of 55~ 100 seconds, suitable for liquid viscosity evaluation.

$ 130.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the diaMeter of the flow hole is 2.53mm, the viscosity range is 25~ 120cSt, and the liquid viscosity is evaluated by measuring the outflow time, which conforms to the ASTM standard design.

$ 130.00

Using titanium anodic oxidation aluminum Cup body and stainless steel filter, 3.4mm pore size design, viscosity measurement range 49-220cSt, Cup mouth deep groove anti-overflow, unique serial number traceability mass.

$ 500.00

Aperture 5.2mm, viscosity measurement range 200-1200cSt, Cup mouth design anti-spill groove, unique serial number logo, matching special bracket to improve test Stability.

$ 497.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the aperture is 3.40mm, the viscosity measurement range is 49~ 220cSt, and the outflow time is 25~ 105 seconds.

$ 130.00

Portable design with long stainless steel handle for easy operation. Outflow aperture 5.8mm, can measure 200-1200cSt viscosity range, corresponding to outflow time 30-100 seconds. Cup body aluminum alloy with stainless steel nozzle, both lightweight and corrosion resistance.

$ 285.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the aperture is 5.2mm, the viscosity measurement range is 200~ 1200cSt, the outflow time is 20~ 105 seconds, and the liquid viscosity is evaluated by the flow time.

$ 130.00

The filter aperture is 2.53mm, the viscosity test range is 25-120cSt, the outflow time is 40-100 seconds, the Cup mouth is designed to prevent liquid overflow, and each pRoduct is engraved with a unique serial number to ensure traceability.

$ 497.00

Outflow diaMeter of 4.1mm, measurement viscosity range of 70~ 370cst, flow time of 30~ 100s, the Cup body is made of titanium anodic oxidation aluminum material, filter and handle are stainless steel, the structure is sturdy and durable.

$ 497.00

Using titanium anodic oxidation aluminum material, the filter is stainless steel, the diaMeter of the flow hole is 4.1mm, the viscosity range is 70-370cSt, the Cup mouth is designed with an anti-spill groove, and each Cup is engraved with a unique serial number.

$ 497.00

Articles

Laboratory dispersers achieve efficient dispersion of paint pigments.
This article introduces how laboratory dispersers efficiently disperse paint pigments. They break up pigment agglomerates through mechanical actions such as shear force, involving three stages: wetting, dispersing, and stabilizing.
Laser particle size analyzer analyzes particle size distribution of paint pigments.
This article introduces the application of laser particle size analyzers in analyzing the particle size distribution of paint pigments. It mentions that the particle size distribution of pigments affects the optical properties, stability, and rheological characteristics of coatings.
Blue-style grinder achieves efficient grinding of ink fineness.
The basket mill is a type of wet grinding equipment used in fine chemical fields such as ink production. It utilizes a high-speed rotating impeller to drive grinding media, generating shear and impact forces on the slurry, thereby dispersing pigment particles and reducing their fineness.
Ink fineness gauge measures the dispersion degree of pigment particles.
The fineness of grind gauge is a method used to evaluate the dispersion level of pigment particles in ink.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Comparison of Pigment Fineness Dispersion between Flat Grinding Mill and Sand Mill
Application of Colorimeter and Color Matching Box in Pigment Color Inspection
A colorimeter and a light booth are two primary tools in pigment color inspection. The colorimeter measures color through photoelectric principles, while the light booth provides a standardized light source environment for visual evaluation of color effects, metamerism, and other phenomena.
Whiteness meter measures the whiteness of white pigments
This article introduces the standard method for measuring the whiteness of white pigments using a whiteness meter. Whiteness is an important optical indicator for evaluating the quality of white pigments, and a whiteness meter can provide objective measurements.
The effect of a flat grinder on the preparation of color paste's tinting strength
This article primarily explores the impact of process parameters on tinting strength during the preparation of color pastes using a flat grinding machine. Tinting strength is a core performance indicator of color pastes, reflecting the coloring efficiency of pigments within the system.
Sieve Residue Analyzer and Sieve Analysis for Determining Pigment Particle Size Distribution
This article introduces how the sieve residue analyzer measures the particle size distribution of pigments through mechanical sieving.
Black-and-white checkerboard and reflectometer for measuring pigment hiding power
This article introduces two methods for measuring the hiding power of pigments: the black-and-white checkerboard method and the reflectometer method.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
Hiding power measurement: Equivalence of mass per unit area method and reflectance contrast method.
Covering power is a key indicator for evaluating the optical performance of coating materials such as paints, inks, and pigments, reflecting the material's ability to conceal the color of the substrate. Accurate determination of covering power is crucial in industrial quality control and research and development.