Non-contact Film Thickness Meter

Non-contact film thickness gauges measure film thickness using optical interference or laser reflection principles without touching the sample surface. They are used to detect the thickness uniformity of coatings, inks, plastic films, and other materials, monitoring process stability in both production lines and laboratories.
Selection
When selecting, consider that the measurement range should cover the sample thickness, and the accuracy must meet process requirements. Choose optical or laser principles based on material properties: transparent films are suitable for interferometry, while metal coatings often use reflection methods. Environmental vibration factors should match the instrument's anti-interference capabilities.

Terms

Instruments

D/8 standard non-contact test, measurement distance 3.0mm, the fastest 0.2 seconds to complete the measurement, support a variety of Color Space and Illuminant, suitable for automatic pRoduction line accurate Color quality control.

$ 8109.00

Using 45/0 ring lighting and concave grating spectroscopy technology, the measurement diaMeter is Φ 20mm, the non-contact measurement distance is 7.5mm, and the chromatic value Repeatability is within 0.03. Color difference formula and chroma index analysis are supported.

$ 8109.00

Adopt 45/0 structure, measurement Repeatability dE * ab ≤ 0.02, Inter-instrument Agreement dE * ab ≤ 0.25, support non-contact detection, waterproof and dustproof IP66, multiple communication interfaces, LED Illuminant long life.

$ 3946.00

Adopt 45/0 ° ring illumination and concave grating spectroscopy, measurement wavelength 400~ 700nm, non-contact distance 7.5mm, avoid sample contamination, support a variety of Measurement modes and camera positioning.

$ 8109.00

Non-contact measurement avoids contact with dangerous objects, Response Time 500ms Fast reading temperature, temperature range -32~ 550 ℃ covers a wide range of scenarios, compact structure and easy to operate.

$ 85.00

Using 45/0 ring lighting and concave grating spectroscopy technology, measurement Wavelength range 400~ 700nm, non-contact distance 7.5mm, avoid sample contamination and damage, support a variety of Measurement modes and camera positioning.

$ 7464.00

Optical inspection structure of 45/0 °, non-contact distance of 7.5mm, measurement wavelength of 400-700nm, avoid sample contamination and damage, support a variety of Measurement modes and High Accuracy Color Analysis.

$ 7464.00

Measurement range 200-20000 rpm, accuracy of +/- (1 × 10 × reading + 1) rpm, support non-contact speed measurement and steering determination function.

$ 198.00

The non-contact grating optocoupler Sensor is used to automatically collect data, with a nominal kinetic energy of 2.207J, supports automatic calculation of intensity and voice broadcast, and has a built-in steel anvil calibration function to improve detection efficiency and accuracy.

$ 369.00

Non-contact automatic whiteboard calibration technology, Inter-instrument Agreement Delta E * 00 < 0.2, high measurement Stability, supports more than 30 Color indicators and 28 kinds of observation Illuminants, compact and easy to carry.

$ 332.00

Non-contact measurement distance 7.5mm +/- 3mm fluctuation is still accurate, the measurement time is only 20ms, built-in auto calibration and Gloss compensation technology to ensure accurate and reliable Color data.

$ 12068.00

Non-contact Sensor to reduce measurement drift, conductivity Measurement range of 0-10000 μS/cm, temperature accuracy of 0.1 ℃, support up to 3 years of battery life and 70 Meters water depth working environment.

$ 1719.00

Using 45/0 ring illumination and concave grating spectroscopy technology, the measurement diaMeter is 20mm, and the non-contact distance is 7.5mm. With 256 pixel dual array CMOS sensor, Wavelength range 400~ 700nm, chromatic value Repeatability Delta E * ab 0.05, supports a variety of Color space and color difference analysis.

$ 7464.00

Repeatability less than or equal to 0.05, display accuracy 0.01, non-contact automatic whiteboard calibration and integrating ball dual optical path design, Type-C interface can be continuously tested 12,000 times when fully charged.

$ 393.00

Repeatability Delta E * ab within 0.1, Measurement time of about 1.0 seconds; Non-contact automatic whiteboard calibration to avoid dirt, integrating ball double light path design to ensure stability, lightweight and portable can be continuously tested 12,000 times.

$ 234.00

Articles