Water Ion Content Detector

Water ion content detectors measure the concentration of dissolved ions in water through conductivity or ion-selective electrodes. They are used to monitor water purity and assess the degree of ion contamination in industrial water, wastewater treatment, and environmental monitoring.
Selection
When selecting, consider the types and range of ions to be detected, matching the characteristics of the samples. Pay attention to the instrument's precision and detection limits to ensure they meet routine requirements. Evaluate the complexity of operation and maintenance costs to adapt to the usage environment. Confirm that the data output method is compatible with the existing system.

Terms

Standards

Instruments

Measurement range 0.23 nm g/L to 23 g/L, temperature compensation 5~ 50 ℃, suitable for high purity water and industrial drainage sodium ion concentration determination, repeatability error does not exceed 0.03pNa.

$ 262.00

With manual and automatic temperature compensation function, Measurement range 0-6 PCL, resolution up to 0.01 PCL, easy operation and intuitive and accurate digital display, suitable for a variety of water quality monitoring scenarios.

$ 382.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, Measurement accuracy +/- 1% F.S., can store 1000 sets of data, suitable for a variety of Ion concentration and water Hardness detection.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 1% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 0.5% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods and 2 to 5 point calibrating, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 0.5% F.S.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, expands memory to store 1000 sets of data, Measurement accuracy of +/- 1% F.S.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods and a variety of concentration units, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement range 5 × 10~ 1M.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods and 13 optional paraMeters, Measurement accuracy +/- 1% F. S, automatically recognizes ion ElectRode and stores 1000 sets of data, with calibrated reminder and USB Communication interface.

$ 864.00

General ion standard solution concentration 1000ppm, suitable for daily ion calibrating, PTFE solution bottle Encasement, capacity 480mL, water Hardness type.

$ 135.00

With manual and automatic temperature compensation function, concentration Measurement range 1 × 10 ^ ²~ 5 × 10 ^ mol/L, the fastest reaction time is less than 4 minutes, support pFe value and iron Ion concentration display.

$ 382.00

7-Inch TFT display clearly displays data, supports 5 Measuring methods such as direct reading method and known addition method, automatically recognizes ion selective ElectRode, expands memory to store 1000 sets of data, Measurement accuracy +/- 0.5% F.S.

$ 864.00

Equipped with 7-inch TFT display, supports 5 measuring methods such as direct reading method and known addition method, Measurement range 1 × 10-6~ 0.1M, accuracy +/- 1% F.S., automatic identification of ion selective ElectRode, can store 1000 sets of data.

$ 864.00

Measurement range 0.000~ 0.3mg/L, can be 100 measurements, supporting special instruments to achieve fast and accurate water quality aluminum ion detection, including a variety of Reagent solutions.

$ 164.00

Measurement range 000-1.000 mg/L, accuracy +/- 0.010mg/L, LED Illuminant and unique reference Detector ensure Stability, support GLP data recording and automatic storage, waterproof design for a variety of environments.

$ 632.00

Articles

Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Key operational points for determining chloride ion content in water using automatic potentiometric titrators
This article introduces a method for measuring chloride ions in water using an automatic potentiometric titrator. It is based on silver nitrate titration, where the endpoint is automatically determined by a sharp change in electrode potential, offering greater accuracy and higher automation compared to traditional methods.
Principles and Advantages of Ion Chromatography for Determining Anions in Water
Ion chromatography separates anions in water samples through an ion exchange column, then reduces background conductivity and enhances signals via a suppressor, and finally measures and quantifies them using a conductivity detector.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.