Capillary ViscoMeter Measurement Apparatus

The capillary viscometer calculates viscosity by measuring the time it takes for a fluid to flow through a standard capillary under constant pressure. It is used for quality control of fluids such as coatings and inks, based on Poiseuille’s law, where the flow time is proportional to viscosity.
Selection
When selecting, consider matching the sample viscosity range with the capillary inner diameter, ensuring temperature control accuracy meets standard requirements, material corrosion resistance suits the testing solvents, timing accuracy reaches 0.1 seconds, and the calibration certificate complies with specifications such as ASTM D445.

Terms

Standards

Instruments

The opaque design is suitable for high viscosity liquid measurement, the viscosity range covers 500 to 2500cSt, and the accurate measurement is based on the principle of capillary tubing flow time proportional to viscosity.

$ 461.00

Using Cannon-Fenske opaque design, suitable for opaque liquid measurement, viscosity measurement range of 240~ 1200cSt, High Accuracy viscosity detection based on capillary tubing outflow time method.

$ 461.00

Measurement range from 10000 to 50000cSt is designed using Ubbelohde DIN standard, and accurate measurement is achieved based on the principle of capillary tubing flow time and viscosity.

$ 461.00

Measurement range from 6000 to 30000cSt, based on the principle of capillary tubing outflow time for accurate viscosity determination, suitable for a variety of liquid samples.

$ 461.00

U-tube countercurrent design, viscosity measurement range of 200-1000cSt, accurate measurement based on the principle of liquid flow time in capillary tubing is proportional to viscosity.

$ 461.00

Ubbelohde DIN standard design, viscosity measurement range of 6~ 30cSt, based on the liquid flow time in capillary tubing is proportional to the viscosity principle, to ensure High Accuracy measurement, suitable for a variety of liquid sample analysis.

$ 461.00

U-tube countercurrent design, Measurement range 20-100cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity to ensure measurement accuracy and Repeatability.

$ 461.00

The liquid kinematic viscosity is measured by capillary method, and the viscosity range covers 0.5~ 2cSt, which is suitable for a variety of liquid samples.

$ 461.00

Using Cannon-Fenske opaque design, viscosity measurement range 4000-20000cSt, based on the principle of capillary tubing outflow time and kinematic viscosity proportional principle, to ensure that the liquid in the upright capillary tubing completely wet pipe wall state flow.

$ 461.00

Ubbelohde ASTM standard design, viscosity measurement range of 10-50cSt, based on capillary tubing flow time and viscosity proportional principle, to ensure measurement accuracy and Repeatability.

$ 461.00

Ubbelohde DIN standard design, viscosity measurement range of 1~ 5cSt, based on capillary tubing flow principle, to ensure High Accuracy and Repeatability, suitable for a variety of liquid analysis.

$ 461.00

Ubbelohde ASTM standard design, viscosity measurement range of 2~ 10cSt, based on the principle of capillary tubing flow time proportional to viscosity, to ensure accurate and reliable measurement.

$ 461.00

U-shaped tube structure design, viscosity measurement range covering 600 to 3000cSt, High Accuracy liquid viscosity measurement based on capillary tubing principle, easy and reliable operation.

$ 461.00

U-tube countercurrent design, viscosity measurement range 0.6-3 cSt, accurate determination of liquid kinematic viscosity based on capillary tubing principle, suitable for a variety of liquid samples.

$ 461.00

Ubbelohde ASTM standard design, viscosity measurement range of 600-3000cSt, based on the principle of capillary tubing flow time and viscosity proportional to achieve accurate measurement.

$ 461.00

Articles