Glass Capillary ViscoMeter

The glass capillary viscometer calculates viscosity by measuring the flow time of liquid in a capillary tube, based on Poiseuille's law. It is used for detecting the viscosity of fluids such as coatings and inks to control production processes.
Selection
When selecting, consider the viscosity range of the liquid being tested to match the capillary specifications, pay attention to temperature control accuracy and sample volume, and choose appropriate cleaning methods and measurement accuracy according to industry standards.

Terms

Standards

Instruments

The liquid kinematic viscosity is measured by capillary method, and the viscosity range covers 0.5~ 2cSt, which is suitable for a variety of liquid samples.

$ 461.00

Measurement range from 6000 to 30000cSt, based on the principle of capillary tubing outflow time for accurate viscosity determination, suitable for a variety of liquid samples.

$ 461.00

Measurement range from 10000 to 50000cSt is designed using Ubbelohde DIN standard, and accurate measurement is achieved based on the principle of capillary tubing flow time and viscosity.

$ 461.00

The opaque design is suitable for high viscosity liquid measurement, the viscosity range covers 500 to 2500cSt, and the accurate measurement is based on the principle of capillary tubing flow time proportional to viscosity.

$ 461.00

U-tube countercurrent design, viscosity measurement range of 200-1000cSt, accurate measurement based on the principle of liquid flow time in capillary tubing is proportional to viscosity.

$ 461.00

Ubbelohde DIN standard design, viscosity measurement range of 6~ 30cSt, based on the liquid flow time in capillary tubing is proportional to the viscosity principle, to ensure High Accuracy measurement, suitable for a variety of liquid sample analysis.

$ 461.00

Using Cannon-Fenske opaque design, viscosity measurement range 4000-20000cSt, based on the principle of capillary tubing outflow time and kinematic viscosity proportional principle, to ensure that the liquid in the upright capillary tubing completely wet pipe wall state flow.

$ 461.00

U-tube countercurrent design, Measurement range 20-100cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity to ensure measurement accuracy and Repeatability.

$ 461.00

U-tube countercurrent design, viscosity measurement range 0.6-3 cSt, accurate determination of liquid kinematic viscosity based on capillary tubing principle, suitable for a variety of liquid samples.

$ 461.00

Ubbelohde ASTM standard design, viscosity measurement range of 10-50cSt, based on capillary tubing flow time and viscosity proportional principle, to ensure measurement accuracy and Repeatability.

$ 461.00

Ubbelohde ASTM standard design, viscosity measurement range of 2~ 10cSt, based on the principle of capillary tubing flow time proportional to viscosity, to ensure accurate and reliable measurement.

$ 461.00

Ubbelohde ASTM standard design, viscosity measurement range 6000-30000cSt, based on capillary tubing flow time and viscosity proportional principle, suitable for high temperature and high viscosity fluid determination.

$ 461.00

Ubbelohde ASTM standard design, viscosity measurement range of 600-3000cSt, based on the principle of capillary tubing flow time and viscosity proportional to achieve accurate measurement.

$ 461.00

Ubbelohde ASTM standard design, viscosity measurement range of 200-1000cSt, based on capillary tubing flow time and viscosity proportional principle, suitable for a variety of liquid sample analysis.

$ 461.00

Using Cannon-Fenske Routine design, the viscosity range is 50-200cSt, and it is easy to operate based on the principle that the flow time of the liquid in the capillary tubing is proportional to the viscosity.

$ 461.00