Silver Electrolytic Thickness Gauge

The silver electrolytic thickness gauge measures the thickness by electrolytically dissolving the silver layer and converting the dissolved electric charge into thickness. It is used for detecting the thickness of silver plating layers and is suitable for quality control of surface silver plating on electronic components, jewelry, and other items.
Selection
When selecting, consider the measurement range covering the sample thickness, accuracy meeting requirements, ease of operation, instrument stability, sample adaptability, maintenance costs, and manufacturer technical support.

Terms

Standards

Instruments

Measurement range 0.03~ 50μm, resolution 0.01μm, support single-layer, multi-layer and alloy platings testing, built-in thermal printer to automatically output statistical reports, suitable for wire and columnar workpieces.

$ 1364.00

Measurement range 0~ 300μm, resolution up to 0.01μm, support multi-layer nickel potential difference analysis, test size optional Φ 2.4mm to Φ 0.8mm.

$ 2978.00

Measurement range 0.1~ 35μm, resolution 0.01μm, can measure more than 20 platings combinations such as Cr, Ni, Cu, etc., support single-layer and composite multi-layer measurement, equipped with 4 quick plating selection buttons to avoid misoperation.

$ 2010.00

Measurement range 0.03-50 um, resolution 0.01um, supports multi-layer platings and alloy platings measurement, with custom hotkeys and LCD display, easy to operate without adjusting Sensitivity.

$ 1235.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Using silver working ElectRode material, temperature range 0-50 ℃, equipped with BNC connector, the shell is ABS material, size 12 * 120mm, suitable for titration applications.

$ 98.00

The mobile sleeve liquid fluid design, equipped with silver ion trapping trap, Glass film resistance is less than 50MΩ, and the shell is made of lead-free Glass to ensure stable measurement and durability.

$ 469.00

Designed with a ceramic liquid complex section and equipped with silver ion trap technology, the membrane resistance is less than 50MΩ, and the lead-free Glass housing ensures durability for wide temperature range measurement.

$ 296.00

Using mobile sleeve liquid complex and silver ion trap structure, the film resistance is less than 50MΩ, Measurement range covers 0-11pH, temperature tolerance 0-80 ℃, to ensure stable and accurate PH detection.

$ 296.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Ceramic sand core salt bridge material, Temperature Measurement range 5-55 ℃, Single salt bridge structure to ensure measurement Stability, U-shaped insert design for easy connection.

$ 91.00

With emission-echo and echo-echo two thickness measurement modes, Measurement range 0.65~ 600mm, Probe type can be automatically identified and zero point calibrated, support anti-measurement Speed of sound function to improve accuracy.

$ 667.00

Measurement range 0.8~ 300mm, accuracy up to +/- 0.04mm, support high-speed measurement 10 times/second, portable design for field use.

$ 706.00

Articles

Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
The coating machine applies a conductive layer (silver nanowires) for flexible display screens onto a PET substrate.
This article introduces the technique of coating a silver nanowire conductive layer on PET substrates using a film applicator. Silver
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Key operational points for determining chloride ion content in water using automatic potentiometric titrators
This article introduces a method for measuring chloride ions in water using an automatic potentiometric titrator. It is based on silver nitrate titration, where the endpoint is automatically determined by a sharp change in electrode potential, offering greater accuracy and higher automation compared to traditional methods.
Preparation of silver nanowire transparent conductive films by the wire bar coating method
The preparation of silver nanowire transparent conductive films using a coating method is an efficient and scalable production process. This article systematically elaborates on the technology from aspects such as principles, materials, processes, performance characterization, and standards.
How to achieve high uniformity in silver nanowire transparent conductive films through wire rod coating
This article introduces how to prepare uniform silver nanowire transparent conductive films using the wire rod coating technique. These films, which use silver nanowires as the conductive material, exhibit high transparency and conductivity, making them suitable for applications such as touch panels.
Selection of Coating Thickness Measurement Methods: Coulometry vs. Dissolution in Electrolytic Thickness Gauges.
This article compares two techniques in electrolytic thickness gauges: the coulometric method and the dissolution method. The coulometric method measures coating thickness through electrochemical dissolution, making it suitable for single-layer metal coatings with simple operation and high accuracy. The dissolution method, on the other hand, measures thickness via chemical dissolution, making it more appropriate for multilayer or complex coatings.