Constant Temperature Aging Test Chamber

The constant temperature aging test chamber maintains a fixed temperature through heating and insulation systems, allowing samples to be continuously exposed under set conditions to simulate the performance changes of materials in stable high-temperature environments. It is used to test the heat resistance and evaluate the lifespan of products such as coatings and plastics, commonly applied in quality inspection and research and development processes.
Selection
When selecting, consider that the temperature range must cover testing needs, uniformity affects result consistency, and the chamber material should be corrosion-resistant. Control accuracy and stability are linked to data reliability, sample capacity should match actual usage, and energy consumption and maintenance costs should be weighed against usage frequency.

Terms

Instruments

300W yellowing resistant bulb provides 365-400nm wavelength ultraviolet, Temperature Uniformity +/- 1 ℃, can simulate the atmospheric environment accelerated testing, one machine multi-purpose support aging Oven function.

$ 1272.00

High Accuracy PID control technology, temperature fluctuation +/- 0.5 ℃, equipped with independent ozone concentration controller long-term stable non-drift, support static tensile specimen and program operation mode.

$ 13128.00

Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable, support 3~ 100 times/h ventilation volume adjustment, to meet a variety of aging test needs.

$ 4463.00

Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, using stainless steel liner and forced circulation system, with automatic ventilation function, ventilation 8~ 20 times/hour adjustable, suitable for material aging test.

$ 8755.00

Temperature control accuracy of +/- 0.5 ℃, Temperature Uniformity adjustable 0~ 200 times/hour, support multi-stage Program setting and automatic diagnosis function, liner made of stainless steel for easy cleaning.

$ 1658.00

Temperature range RT + 20~ 250 ℃, Fluctuation +/- 0.5 ℃, equipped with low speed swirl/spin turntable to ensure test uniformity, support multi-stage programmable control and ventilation regulation, easy data recording and fault diagnosis.

$ 2447.00

Using heating wire and PT100 temperature transducer, Temperature Fluctuation +/- 0.5 ℃, support 0~ 999H light time setting, 360 degree swirl/spin sample holder and imported concentration Analyzer to ensure test accuracy.

$ 11369.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, temperature fluctuation is only +/- 0.5 ℃.

$ 12015.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, Temperature Fluctuation control within +/- 0.5 ℃.

$ 16017.00

The heating wire is used to achieve rapid heating, the temperature fluctuation is only +/- 0.5 ℃, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, supports dynamic static test mode, and meets a variety of test needs.

$ 14419.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 5947.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.

$ 6431.00

The equipment adopts high-density fiberglass cotton insulation layer Film thickness 150mm, Temperature Uniformity up to +/- 1 ℃, with automatic ventilation system adjustable ventilation volume 8-20 times/hour, sample holder can be swirl/spin design to enhance test uniformity.

$ 5770.00

Temperature control range -40~ 150 ℃, volume 800L, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature cycle change test, support aging test and various standard verification.

$ 7625.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360-degree swirl/spin sample holder and 12-16mm/s gas flow rate, support 0-9999 hours time setting, with leakage overtemperature multiple safety protection.

$ 13209.00

Articles

Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.