Temperature range -5~ 100 ℃, Temperature Fluctuation and Uniformity up to +/- 0.05 ℃, support a variety of temperature control media, with RS485 interface remote control and multiple safety protection functions.
Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.
The double Compressor cascade refrigeration system is adopted, with fast cooling and low noise, Temperature Fluctuation +/- 0.05 ° C, and pump Flow rate of 8L/min to ensure the uniformity of liquid in the Tank and reliable operation.
Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.
Imported Pt100 temperature sensor and dual Compressor refrigeration system, rapid cooling and low noise, Temperature Fluctuation +/- 0.05 ℃, 6L volume Tank with 8L/min circulating pump to ensure Temperature uniformity.
Platinum Sensor ensures linear and stable measurement, built-in temperature sensor real-time compensation, Conductivity Detector cell constant K = 1, Low noise Shielding line design effectively reduces signal interference.
Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.
Using fluorine-free refrigeration system and mirror stainless steel liner, temperature range -40~ 65 ℃, with microcomputer intelligent control and independent temperature limit alarm function, support multi-stage programming and RS-485 communication interface.
Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. The U-shaped return design realizes a highly uniform flow field temperature field. Temperature resolution reaches 0.0001 ° C. It has multiple Safety protection devices such as low water level anti-dry burning and Compressor overload protection.
Imported PT100 temperature sensor and double Compressor cascade refrigeration system, high refrigeration efficiency and low noise, Temperature Fluctuation +/- 0.05 ℃, Tank volume 30L, Circulating pump Flow rate 10L/min to ensure Temperature uniformity.
Built-in PT100 temperature sensor, temperature range 0~ 405 ℃, stainless steel shell, suitable for high temperature liquid temperature measurement, real-time accurate monitoring.
Can achieve -80 ℃ low temperature control, built-in two-stage magnetic stirring system, Speed range 100-1200RPM, equipped with high temperature and over-temperature protection functions, environmentally friendly refrigerant to ensure safe operation.
Adopt two-stage Compressor cascade refrigeration technology implementation -40 ℃ low temperature, PID temperature control with proportional refrigeration technology to improve the temperature Stability to +/- 0.5 ℃, DC brushless motor supports 100-1200RPM stepless speed regulation, with a variety of alarm and automatic recovery function.
Adopt double Compressor cascade refrigeration system, high refrigeration efficiency and low noise. Temperature Fluctuation +/- 0.05 ℃, resolution 0.1 ℃. 30L volume Tank body overall foaming insulation, pump Flow rate 10L/min to ensure Temperature uniformity.