Low Temperature Cold Resistance Test Chamber

The low-temperature cold resistance test chamber creates a constant low-temperature environment through a refrigeration system to simulate the performance changes of materials under cold conditions. It is used to test the embrittlement and shrinkage of products such as coatings and plastics at low temperatures, commonly applied in the cold resistance verification of automotive components and electronic devices.
Selection
When selecting, pay attention to the temperature range to ensure it covers the testing standards, as uniformity affects data accuracy, and the cooling rate should match actual requirements. The cabinet material should be corrosion-resistant, recording functions should facilitate process tracking, space capacity should be determined based on sample size, and energy consumption and maintenance costs need to be comprehensively considered.

Terms

Instruments

Temperature range -25 ℃, temperature control accuracy +/- 1 ℃, can simulate the natural low temperature environment for bending test, observe material changes, determine the degree of cold resistance.

$ 6770.00

The independent control structure of the cold and hot box is adopted, with a temperature conversion time of less than 15 seconds and a temperature recovery time of less than 5 minutes. It is equipped with multiple safety interlock protection and standard lead hole design to ensure efficient and safe testing.

$ 34606.00

Temperature control accuracy of +/- 0.3 ℃, support for the installation of a variety of folding fixture, suitable for different materials in low temperature environment folding performance test.

$ 6205.00

With the independent control structure of the cold and hot box, the temperature conversion takes only 15 seconds and the recovery time does not exceed 5 minutes. The temperature fluctuation in the sample area is controlled within +/- 0.5 ° C, the load-bearing capacity is up to 40kg, and it is equipped with safety interlock protection and 7-inch Touchscreen controller.

$ 38608.00

Adopt independent control structure of hot and cold box, temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, equipped with safety interlock protection and 7-inch Touchscreen controller, support long-term adjustable test.

$ 42981.00

Adopting independent control design of hot and cold box, the temperature conversion time does not exceed 15 seconds, and the recovery time is within 5 minutes. Equipped with safety interlock function and standard lead hole tube, it enhances test efficiency and operation safety.

$ 29120.00

Temperature range -30 ℃ to + 100 ℃, equipped with stainless steel inner and outer boxes and environmentally friendly refrigerant, supports multi-station fixture testing, can precisely control the folding mode and record data changes in real time.

$ 6113.00

Temperature range of -40~ 150 ℃ and 20~ 98% Humidity control, anti-condensation design of laminated Glass viewing window, support multi-stage program editing and fast slope control, meet a variety of standard test requirements.

$ 9271.00

Using stainless steel inner and outer box material, Temperature control accuracy of +/- 0.3 ℃, equipped with a variety of fixtures, suitable for different materials cold test, cooling speed is fast, 45 minutes up to -30 ℃.

$ 5468.00

Temperature range -40~ 150 ℃, Humidity range 20~ 98% RH, with multi-stage program editing and fast slope control function, double-decked air tight and sweat-proof viewing window design.

$ 5237.00

It is suitable for low temperature bending resistance test of 32-63mm diaMeter silicon core tube. The sample needs to be kept at -20 ℃ +/- 2 ℃ for 2 hours, and there is no cracking or obvious stress blushing phenomenon after testing.

$ 2450.00

Temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, cold and hot box independent control does not interfere with each other, with sample area temperature fluctuation ≤ +/- 0.5 ℃ High Accuracy thermostatic performance, improve test reliability.

$ 25328.00

Adopting the independent control structure of the cold and hot box, the temperature conversion time is ≤ 15 seconds, and the temperature recovery is ≤ 5 minutes. Equipped with safety interlock protection, the temperature fluctuation in the sample area is ≤ +/- 0.5 ° C, supporting long-term stable operation.

$ 25328.00

High borosilicate Glass material, corrosion resistance and high and low temperature resistance, strong ability to withstand thermal Impact; vacuum negative pressure can reach 0.095MPa, support material reaction under negative pressure; Overhead Stirrer Rotation speed 50-500rpm, torque 70N.cm, suitable for a variety of viscosity materials.

$ 2465.00

Adopting independently controlled hot and cold box structure, the temperature conversion time does not exceed 15 seconds, the recovery time is within 5 minutes, and it is equipped with a 7-inch Touchscreen controller with an accuracy of +/- 0.1 ° C, supporting a sample load of 20kg, suitable for a variety of testing needs.

$ 22471.00