Metalurgical Inspection Microscope

A metallurgical microscope uses an optical system to magnify the surface of metal samples and observes the metallographic structure through reflected light. It is used to analyze the grain structure, defects, and heat treatment effects of metal materials, and to test material properties in the fields of metallurgy and mechanical manufacturing.
Selection
When selecting, consider that the magnification range should cover the detection requirements, and the numerical aperture of the objective lens affects resolution. Choose the stage size based on the sample dimensions, and ensure that brightfield or darkfield illumination matches the observation target. Maintenance costs and operational complexity should align with the usage scenario.

Terms

Standards

Instruments

Infinity Optical inspection system and Modular function design can realize polarization and dark field observation; Coarse fretting coaxial focusing system fretting grid value of 2 μ m, guide column lifting device to adapt to different Film thickness workpiece detection needs.

$ 2252.00

Optical inspection system and Modular design can be used to upgrade the functions of polarization and dark field observation; coarse fretting coaxial focusing system fretting grid value of 2 μ m, cylindrical roller guide drive to ensure smooth lifting, suitable for different Film thickness workpiece detection.

$ 6012.00

Optical inspection system with infinity, 40X-1000X magnification range and N.A.1.25 Abbe condenser, support digitalization observation and a variety of auxiliary equipment expansion.

$ 2060.00

Optical inspection system with infinity, support 40X-1600X magnification range, with Abbe condenser and coaxial focusing mechanism, can realize high-resolution real-time observation and digital storage function.

$ 1213.00

Infinity Optical inspection system provides high resolution images, equipped with six hole objective converter and N.A.1.1 Abbe condenser, supports autofocus and multiple Observation methods, magnification 40X-1000X.

$ 11660.00

Optical inspection system with infinity, 40X-1000X magnification range, 5 million pixel CMOS camera and coaxial focusing mechanism for vertical lighting and fluorescent device expansion.

$ 1758.00

Optical inspection system with infinity, phase contrast condenser and 5 million pixel CMOS camera, support 40X-1600X magnification, geometric measurement analysis function.

$ 3147.00

Optical inspection system to improve imagery mass, working distance up to 20mm, support a variety of observation methods, magnification 40X-1000X, to meet different experimental needs.

$ 787.00

Infinity Optical inspection system, support a variety of Observation methods, equipped with six-hole objective lens converter and N.A.1.1 Abbe condenser, magnification 40X-1000X, easy and flexible operation.

$ 10449.00

Equipped with UIS Infinity Optical inspection system, supports phase contrast observation and dark field function, magnification 40X-1600X, uses 6V/20W halogen lamp Kohler lighting, expandable fluorescent and vertical lighting device.

$ 3449.00

Optical inspection system with infinite distance, equipped with phase contrast condenser and variable light bar, magnification 40X-1600X, support phase contrast objective and brightfield observation, expandable fluorescence and other auxiliary devices.

$ 2239.00

Optical inspection system with infinite distance, long working distance flat-field objective with non-stress, fretting grid value of 2 μ m, 360 ° adjustable rotating stage, support polarization observation and microphotography.

$ 2429.00

Optical inspection system infinity to ensure good imagery mass, 70mm long working distance condenser to support high culture dish observation, coarse fretting coaxial focusing system fretting grid value of 2μm to achieve accurate focusing.

$ 2946.00

Optical inspection system, working distance up to 70mm, support phase contrast observation and a variety of culture dish adaptation, compact and stable body design to meet the requirements of vibration protection, providing clear microscopic imagery effect.

$ 3653.00

Optical inspection system with infinite distance, stress-free flat-field objective, fretting grid value of 2 μ m, rotating stage with 360 ° scale, support trinocular observation and microphotography, table Travel 30 mm vertically.

$ 2784.00

Articles

How to choose a single-column electronic universal testing machine based on the maximum test force
This article introduces how to select a single-column electronic universal testing machine based on the maximum test force. First, determine the strength range according to the material type and standard, such as plastics, metals, etc. Then, calculate the maximum force based on the tensile strength and specimen area, and multiply it by a safety factor of 1.3 to 1.5.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.