Adopt air condensation technology instead of water condensation, Temperature control accuracy +/- 2 ℃, equipped with 12 heating holes, heating up to 170 ℃ time is less than 30 minutes, support segmented timing function.
Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable, support 3~ 100 times/h ventilation volume adjustment, to meet a variety of aging test needs.
Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, using stainless steel liner and forced circulation system, with automatic ventilation function, ventilation 8~ 20 times/hour adjustable, suitable for material aging test.
Double-decked serpentine coil condensation design, chilled down area of 0.15m ², maximum evaporation capacity of 22ml/min, with automatic lifting function and anti-dry burn Safety protection, to ensure efficient and safe Sample Handling.
With 5~ 200 times/hour air volume adjustment, temperature control accuracy +/- 0.5 ℃, liner with 1.0mm stainless steel plate, with dynamic turntable and high temperature protection system, suitable for material aging test.
Using nitrile rubber material, length 100mm diaMeter 20mm, with excellent oil resistance and aging performance, suitable for inks proofing operation.
300W yellowing resistant bulb provides 365-400nm wavelength ultraviolet, Temperature Uniformity +/- 1 ℃, can simulate the atmospheric environment accelerated testing, one machine multi-purpose support aging Oven function.
The 300W OSRAM bulb provides 365-400nm wavelength UV, Temperature Uniformity +/- 1 ℃, can be tested for yellowing resistance and aging at the same time, and the turntable Rotation speed 10 +/- 2rpm ensures uniform sample irradiation.
The circular stainless steel liner is used to prevent condensation and dripping, the copper tube bell mouth is designed with good air tightness and low water consumption, and the special high temperature foaming material improves the pressure life. It is equipped with a 16L large-capacity water Tank and an automatic water replenishment system.
Temperature control accuracy of +/- 0.5 ℃, air change 3-150 times/hour adjustable, using SUS304 stainless steel inner box and PID automatic calculation function to ensure test Stability and data accuracy.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, temperature fluctuation is only +/- 0.5 ℃.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, Temperature Fluctuation control within +/- 0.5 ℃.
The heating wire is used to achieve rapid heating, the temperature fluctuation is only +/- 0.5 ℃, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, supports dynamic static test mode, and meets a variety of test needs.
Using heating wire and PT100 temperature transducer, Temperature Fluctuation +/- 0.5 ℃, support 0~ 999H light time setting, 360 degree swirl/spin sample holder and imported concentration Analyzer to ensure test accuracy.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360-degree swirl/spin sample holder and 12-16mm/s gas flow rate, support 0-9999 hours time setting, with leakage overtemperature multiple safety protection.