Vapor Aging Test Chamber

The steam aging test chamber simulates high-temperature and high-humidity conditions to conduct accelerated aging tests on materials by generating a constant-temperature and constant-humidity saturated water vapor environment. Its principle involves heating water to produce steam, maintaining stable temperature and humidity in a sealed space, thereby inducing reactions such as oxidation and hydrolysis on the surface of samples. This equipment is used to evaluate the corrosion resistance and durability of materials such as coatings, plastics, and metals. It is commonly applied in quality testing for electronic components, automotive parts, and packaging materials.
Selection
When selecting a steam aging test chamber, consider the temperature and humidity range and control accuracy required by the testing standards. Typically, the saturated steam temperature ranges from 100 to 130℃. The chamber body material should be corrosion-resistant, such as stainless steel. Determine the internal volume based on sample size and quantity. Pay attention to indicators like temperature uniformity and fluctuation. The chamber must have safety protection features, such as overtemperature protection. Check the design for condensate collection and drainage. Refer to the manufacturer's technical support and after-sales service quality.

Terms

Standards

Instruments

Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable, support 3~ 100 times/h ventilation volume adjustment, to meet a variety of aging test needs.

$ 4463.00

300W yellowing resistant bulb provides 365-400nm wavelength ultraviolet, Temperature Uniformity +/- 1 ℃, can simulate the atmospheric environment accelerated testing, one machine multi-purpose support aging Oven function.

$ 1272.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, temperature fluctuation is only +/- 0.5 ℃.

$ 12015.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, Temperature Fluctuation control within +/- 0.5 ℃.

$ 16017.00

The heating wire is used to achieve rapid heating, the temperature fluctuation is only +/- 0.5 ℃, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, supports dynamic static test mode, and meets a variety of test needs.

$ 14419.00

Using heating wire and PT100 temperature transducer, Temperature Fluctuation +/- 0.5 ℃, support 0~ 999H light time setting, 360 degree swirl/spin sample holder and imported concentration Analyzer to ensure test accuracy.

$ 11369.00

Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, using stainless steel liner and forced circulation system, with automatic ventilation function, ventilation 8~ 20 times/hour adjustable, suitable for material aging test.

$ 8755.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360-degree swirl/spin sample holder and 12-16mm/s gas flow rate, support 0-9999 hours time setting, with leakage overtemperature multiple safety protection.

$ 13209.00

High Accuracy PID control technology, temperature fluctuation +/- 0.5 ℃, equipped with independent ozone concentration controller long-term stable non-drift, support static tensile specimen and program operation mode.

$ 13128.00

Imported stainless steel liner and independent ozone concentration controller, temperature control accuracy of +/- 0.5 ℃, equipped with static tensile fixture and rotational speed adjustable sample rack, support long-term stable operation.

$ 10643.00

The 300W OSRAM bulb provides 365-400nm wavelength UV, Temperature Uniformity +/- 1 ℃, can be tested for yellowing resistance and aging at the same time, and the turntable Rotation speed 10 +/- 2rpm ensures uniform sample irradiation.

$ 1143.00

Adopt stainless steel liner and hot air circulation system, Temperature Uniformity +/- 2 ℃, ventilation time 3min-100h adjustable, equipped with low speed turntable and multiple safety protection devices.

$ 4850.00

Adopt silent ozone generator and UltravioletDetector, ozone concentration control accuracy +/- 2pphm, support static tensile and dynamic tensile test, Temperature Uniformity ≤ 2 ℃ to meet a variety of test conditions

$ 8529.00

Temperature control accuracy of +/- 0.5 ℃, Temperature Uniformity adjustable 0~ 200 times/hour, support multi-stage Program setting and automatic diagnosis function, liner made of stainless steel for easy cleaning.

$ 1658.00

Temperature range RT + 20~ 250 ℃, Fluctuation +/- 0.5 ℃, equipped with low speed swirl/spin turntable to ensure test uniformity, support multi-stage programmable control and ventilation regulation, easy data recording and fault diagnosis.

$ 2447.00

Articles

Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Xenon lamp aging test chamber for testing film weather resistance.
This article introduces how a xenon lamp weathering test chamber tests the weatherability of films. It uses a xenon lamp to simulate sunlight and controls conditions such as temperature and humidity to accelerate the aging process of the film, thereby evaluating its performance changes in outdoor environments.
Comparison between Xenon Arc Weathering Chambers and UV Aging Chambers in Weathering Evaluation
Comparison between Xenon Lamp Aging Test Chambers and UV Aging Test Chambers in Weathering Evaluation
UV aging test chamber for evaluating the discoloration degree of resin weather resistance
This article introduces the method of using a UV aging test chamber to examine the degree of weather-induced discoloration in resins.
Xenon lamp aging test chamber evaluates the long-term outdoor performance of resins.
Xenon lamp aging test chambers simulate environmental conditions such as sunlight, temperature, and humidity to accelerate the testing of the weather resistance of materials like resins in a laboratory setting.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
UV aging test chamber evaluates the aging resistance of artificial leather.
This article aims to elucidate the principles, methods, evaluation criteria, and related technical considerations for assessing the aging resistance of artificial leather using a UV aging test chamber.