Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, with automatic ventilation system can adjust the ventilation volume 8~ 20 times/hour, sample holder can swirl/spin to ensure test uniformity.
Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, stainless steel liner and automatic ventilation system, support sample holder swirl/spin and forced ventilation functions, suitable for material heat resistance testing.
Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, using stainless steel liner and forced circulation system, with automatic ventilation function, ventilation 8~ 20 times/hour adjustable, suitable for material aging test.
Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, stainless steel swivel and automatic ventilation system, support sample swirl/spin and independent heating control, suitable for material heat resistance testing.
The equipment adopts high-density fiberglass cotton insulation layer Film thickness 150mm, Temperature Uniformity up to +/- 1 ℃, with automatic ventilation system adjustable ventilation volume 8-20 times/hour, sample holder can be swirl/spin design to enhance test uniformity.
Adopt stainless steel shaft impeller forced convection cycle, Temperature Uniformity +/- 1 ℃, adjustable ventilation rate 8-20 times/hour, with independent ventilation system and sample holder swirl/spin function.
Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable, support 3~ 100 times/h ventilation volume adjustment, to meet a variety of aging test needs.
Adopt stainless steel liner and 150mm insulation layer, Temperature Uniformity +/- 1 ℃, with automatic ventilation function and adjustable ventilation rate 8-20 times/hour, support sample holder swirl/spin test.
Temperature range RT + 20~ 250 ℃, Fluctuation +/- 0.5 ℃, equipped with low speed swirl/spin turntable to ensure test uniformity, support multi-stage programmable control and ventilation regulation, easy data recording and fault diagnosis.
Adopt high temperature fan and special air duct to ensure temperature uniformity, equipped with low speed turntable; Temperature range RT + 10~ 200 ℃, uniformity +/- 2 ℃, support 3-100 times/h ventilation volume adjustment.
With 5~ 200 times/hour air volume adjustment, temperature control accuracy +/- 0.5 ℃, liner with 1.0mm stainless steel plate, with dynamic turntable and high temperature protection system, suitable for material aging test.
Adopt stainless steel liner and hot air circulation system, Temperature Uniformity +/- 2 ℃, ventilation time 3min-100h adjustable, equipped with low speed turntable and multiple safety protection devices.
With -10 ℃~ 50 ℃ temperature range and 5% RH~ 98% RH Humidity range, accuracy of +/- 1.5 ℃ and +/- 5% RH, support unit conversion and automatic shutdown, easy and reliable operation.
Capacitive polymer film Humidity Sensor and semiconductor temperature sensor are used. The temperature error is +/- 0.2 ℃, Humidity error is +/- 2.0%, and wet bulb, dew point, dry bulb temperature switching and 99 groups of Data storage are supported.
Using split Sensor design, temperature range -20~ 60 ℃, humidity range 10~ 95% RH, Sampling rate 0.4 seconds, with MAX Maximum hold and automatic shutdown function, compact and easy to carry.