500G to 10g multi-stage load selection, Test speed up to 80 times/minute, equipped with multi-function fixture and LED digital display counter to support long-term Stability testing needs.
The device uses a 35mm/s scribe traverse speed, a load range of 20N, and can clamp a test board up to 100x150x1.6mm. It contacts the substrate through a voltMeter indicator tool to achieve failure assessment from trace to damage.
Ubbelohde ASTM standard design, viscosity measurement range of 10-50cSt, based on capillary tubing flow time and viscosity proportional principle, to ensure measurement accuracy and Repeatability.
Pure white paper surface sealed, size 194x286mm, ASTM standard, support hiding power measurement and levelling sag test, matching Applicator Rod can obtain uniform coating results.
Ubbelohde ASTM standard design, viscosity measurement range of 2~ 10cSt, based on the principle of capillary tubing flow time proportional to viscosity, to ensure accurate and reliable measurement.
Ubbelohde ASTM standard design, viscosity measurement range of 200-1000cSt, based on capillary tubing flow time and viscosity proportional principle, suitable for a variety of liquid sample analysis.
Ubbelohde ASTM standard design, viscosity measurement range of 600-3000cSt, based on the principle of capillary tubing flow time and viscosity proportional to achieve accurate measurement.
Ubbelohde ASTM standard design, viscosity measurement range of 2000 to 10000cSt, based on capillary tubing flow time and viscosity proportional principle, to ensure High Accuracy.
Ubbelohde ASTM standard design, viscosity measurement range 6000-30000cSt, based on capillary tubing flow time and viscosity proportional principle, suitable for high temperature and high viscosity fluid determination.
Ubbelohde ASTM standard design, viscosity measurement range of 20000-100000cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity, to ensure accurate determination of high viscosity liquids.
Ubbelohde ASTM standard design, viscosity measurement range of 20-100cSt, based on the principle of capillary tubing can accurately determine the kinematic viscosity of liquids, suitable for a variety of fluid analysis.
Black and white half design, size 98x152mm, ASTM standard, can accurately measure Coating hiding power, support transparent film and plastic pRoducts hiding ratio detection.
Ubbelohde ASTM standard design, viscosity measurement range of 100-500cSt, based on the liquid flow time in capillary tubing is proportional to the viscosity principle, to ensure accurate determination.
Ubbelohde ASTM standard design, viscosity measurement range of 10,000-50000cSt, based on the principle of capillary tubing flow time and kinematic viscosity proportional to ensure accurate determination of high viscosity liquids.
Based on the principle that the flow time of the liquid in capillary tubing is proportional to the viscosity, the Ubbelohde ASTM standard design is adopted. Measurement range covers 1000-5000cSt, which is suitable for accurate determination of liquids of different viscosities.