Air exchange aging test chamber

The ventilated aging test chamber accelerates the aging process of materials by simulating natural aging environments through the use of circulating air and temperature and humidity control. It is used to evaluate the performance changes of materials such as coatings and plastics under long-term use.
Selection
When selecting, consider the test standard requirements, match sample dimensions and quantity, confirm the temperature and humidity range and control accuracy, check the adjustability of the air exchange rate, and evaluate equipment stability and maintenance convenience.

Terms

Standards

Instruments

Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, using stainless steel liner and forced circulation system, with automatic ventilation function, ventilation 8~ 20 times/hour adjustable, suitable for material aging test.

$ 8646.00

Adopt stainless steel liner and hot air circulation system, Temperature Uniformity +/- 2 ℃, ventilation time 3min-100h adjustable, equipped with low speed turntable and multiple safety protection devices.

$ 4790.00

Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable and hot air circulation system to ensure stable and uniform temperature in the working room.

$ 7945.00

The use of high temperature fan and special air duct to achieve uniform heating, equipped with low-speed turntable to ensure uniform heating of the sample, Temperature Fluctuation control within +/- 0.5 ℃, ventilation can be adjusted within the range of 3-100 times/hour.

$ 6479.00

The equipment adopts high-density fiberglass cotton insulation layer Film thickness 150mm, Temperature Uniformity up to +/- 1 ℃, with automatic ventilation system adjustable ventilation volume 8-20 times/hour, sample holder can be swirl/spin design to enhance test uniformity.

$ 5698.00

Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable, support 3~ 100 times/h ventilation volume adjustment, to meet a variety of aging test needs.

$ 4407.00

Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, with automatic ventilation system can adjust the ventilation volume 8~ 20 times/hour, sample holder can swirl/spin to ensure test uniformity.

$ 3897.00

300W yellowing resistant bulb provides 365-400nm wavelength ultraviolet, Temperature Uniformity +/- 1 ℃, can simulate the atmospheric environment accelerated testing, one machine multi-purpose support aging Oven function.

$ 1257.00

Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, stainless steel swivel and automatic ventilation system, support sample swirl/spin and independent heating control, suitable for material heat resistance testing.

$ 7132.00

Adopt stainless steel shaft impeller forced convection cycle, Temperature Uniformity +/- 1 ℃, adjustable ventilation rate 8-20 times/hour, with independent ventilation system and sample holder swirl/spin function.

$ 4264.00

Equipped with forced hot air circulation system to ensure uniform temperature distribution, temperature control accuracy of +/- 0.3 ℃, support 0-999 hours timing and nine-point fault warning function, using PID automatic calculation to reduce manual setting inconvenience.

$ 2272.00

Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, stainless steel liner and automatic ventilation system, support sample holder swirl/spin and forced ventilation functions, suitable for material heat resistance testing.

$ 4104.00

Adopt high temperature fan and special air duct to ensure temperature uniformity, equipped with low speed turntable; Temperature range RT + 10~ 200 ℃, uniformity +/- 2 ℃, support 3-100 times/h ventilation volume adjustment.

$ 5969.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, temperature fluctuation is only +/- 0.5 ℃.

$ 11865.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, Temperature Fluctuation control within +/- 0.5 ℃.

$ 15817.00