Three-axis dispersing mixer

The three-axis dispersing mixer achieves shear, convection, and diffusion effects through the synchronous rotation of three independent rotating shafts. It is used for mixing and dispersing high-viscosity materials in industries such as coatings and inks, capable of simultaneously performing stirring, dispersing, and emulsifying operations. It is suitable for processing viscous materials requiring multi-directional mixing.
Selection
When selecting, consider matching the material viscosity with the speed range, determine the volume specification based on the processing capacity, configure wall scraping or vacuum functions according to process requirements, choose the material of contact components based on the material's corrosiveness, and determine the machine size in combination with the installation space.

Terms

Standards

Instruments

Three-axis linkage automatic precision control, intelligent cutting can change the amount of feed according to the hardness of materials, the maximum cutting section is 100 × 100mm, equipped with mobile magnetic filtrate circulating water Tank and fully enclosed safety structure.

$ 21059.00

Using three-axis automatic precision control, the maximum cutting section of 200 * 150mm, with intelligent cutting function can change the amount of feed according to the hardness of materials, fully enclosed structure to ensure safe operation, mobile magnetic filtrate circulating water Tank to improve the cutting mass.

$ 37930.00

With three-axis linkage automatic precision control, the maximum cutting section of 100 × 100mm, intelligent cutting can change the amount of feed according to the hardness of materials, fully enclosed structure to ensure safe operation, mobile magnetic filtrate circulating water Tank to improve the surface mass of the sample.

$ 17630.00

Adopt three-axis linkage system, spindle Rotation speed 24000rpm, accuracy resolution 0.003mm, support a variety of spline and notch processing, with material Water-Cooled and processing compensation functions, one processing can complete a variety of splines.

$ 6205.00

Test speed 0-300 times/minute, strike force 0-500gf adjustable, automatically detect key damage and stop within 8 seconds, support multi-pRoduct testing.

$ 1656.00

Simultaneous measurement of three-axis or single-axis vibration paraMeters, Frequency range up to 10Hz-10KHz, Support for Displacement, Speed and Acceleration Measurement modes, with AC signal output for auscultation recording.

$ 703.00

Adopt 00 grade granite structure to ensure stable accuracy, three-axis imported ball screw to ensure repeability positioning accuracy, equipped with programmable LED light source and 1/3 industrial digital color camera, support autofocus and a variety of geometric measurement functions.

$ 9158.00

Adopt 00 grade granite structure to ensure stable accuracy, three-axis imported ball screw to ensure repeability positioning accuracy, equipped with programmable LED light source and industrial digital color camera, support autofocus and a variety of geometric measurement functions.

$ 10167.00

Using ABB variable frequency motor to provide 7.5kW power, the maximum cutting section of 300 * 150mm, support intelligent cutting according to the hardness of materials automatically adjust the amount of feed, equipped with mobile magnetic filtrate circulating water Tank to ensure that the surface of the sample without burns.

$ 48161.00

Using three-axis linkage automatic control, the maximum cutting section of 120 × 120mm, intelligent cutting can be changed according to the hardness of materials into the knife, equipped with mobile magnetic filtrate circulating water Tank to ensure that the sample surface without burns.

$ 25860.00

Adopt three-axis linkage system, the maximum machining error is only 0.05mm, support a variety of sample shape processing, such as bar, dumbbell and irregular graphics, spindle Rotation speed 24000rpm.

$ 5883.00

Using three eccentric axis equilibrate drive to ensure uniform sample oscillation, Speed range 40~ 300rpm, swing amplitude 35mm, can run continuously for a long time, Rotation speed monitoring and mild start function.

$ 2644.00

Using three eccentric shaft equilibrate drive to ensure uniform sample oscillation, Temperature Fluctuation +/- 0.2 ℃, support long-term continuous operation, low heat dissipation DC motor maintenance-free, power-off automatically save paraMeters.

$ 2841.00

Using three eccentric axis equilibrate drive to ensure uniform sample oscillation, Oscillation Frequency 40~ 300rpm adjustable, swing amplitude 35mm, support long-term continuous operation and Rotation speed monitoring and mild start function.

$ 2939.00

Using three eccentric axis equilibrate drive to ensure uniform sample oscillation, Speed range 40~ 300rpm, swing amplitude 35mm, support long-term continuous operation, with gentle start and Rotation speed monitoring function, to prevent sample spill and equipment failure.

$ 2447.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Capacity Matching for Laboratory Small Dispersers and Pilot Dispersers
This article primarily discusses how to select the appropriate disperser for laboratory research and process development.
Laboratory dispersers achieve efficient dispersion of paint pigments.
This article introduces how laboratory dispersers efficiently disperse paint pigments. They break up pigment agglomerates through mechanical actions such as shear force, involving three stages: wetting, dispersing, and stabilizing.
Selection of disperser speed range and matching of dispersing disc form with container
This article discusses the technical points in the selection of a disperser, including the speed range, the form of the dispersion disc, and the matching with the container.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
The laboratory pulp wet disintegrator is used for pulp disintegration treatment.
The laboratory pulp wet disintegrator is a device used to simulate the industrial pulping process. It disperses pulp fibers into individual fibers or small fiber bundles through mechanical action, while simultaneously promoting fiber swelling and fibrillation, thereby providing standardized samples for subsequent performance evaluation.
The impact of the disperser impeller structure on dispersion effectiveness.
This article mainly discusses how the impeller structure of a disperser affects the dispersion effectiveness. The impeller is the core component of a disperser, and its design directly influences the uniformity and stability of the final mixture.
Application of High-Speed Disperser in the Preparation of Water-Based Inks
This article introduces the application of a high-speed disperser in the preparation of water-based inks. It first explains the working principle of the equipment, which involves generating shear forces through high-speed rotation to disperse particles.
Ink fineness gauge measures the dispersion degree of pigment particles.
The fineness of grind gauge is a method used to evaluate the dispersion level of pigment particles in ink.