Metal Impact Tester

The metal impact tester measures the energy absorbed by a metal specimen upon fracture by striking it with a pendulum, reflecting the material's toughness. It is used to assess the fracture resistance of metals under impact loads and is commonly employed in material quality control and failure analysis.
Selection
When selecting a metal impact tester, it is essential to match the testing standards, confirm that the impact energy range covers the material being tested, check the compatibility of the anvil and pendulum specifications, verify that the temperature control function meets the testing requirements, and consider the structural rigidity and safety protection measures of the equipment.

Terms

Standards

Instruments

The impact height is adjustable from 0 to 100 cm, with optional impactor weights of 1000 g or 2 lbs. It is equipped with a depth control ring and a mold base, supporting ISO 6272 and ASTM D2794 standard tests.

$ 752.00

Impact energy 2.7mJ, Impact mass 3.0g, tungsten carbide ball head Hardness up to 1600HV, suitable for asperity 0.4um surface, providing accurate Hardness measurement.

$ 167.00

Impact energy 90mJ, Impact mass 20g, can detect the maximum Hardness 650HV, Cedar depth 41-53μm, suitable for asperity 6.3μm surface.

$ 364.00

Impact energy 11mJ, Impact mass 7.8g, tungsten carbide ball head Hardness 1600HV, suitable for asperity 1.6μm surface, measurable minimum thickness 0.8mm hardened layer, indication Repeatability 12HLD + 15.

$ 167.00

Impact height up to 120 cm, weight weight mass 1000g, no secondary rebound after impact, to ensure accurate and reliable test results, suitable for film impact performance evaluation.

$ 370.00

Impact energy 11mJ, Impact device mass 50g, ball head diaMeter 3mm, Hardness measurement hole or cylinder, suitable for a variety of metal hardness of materials testing.

$ 162.00

Impact height 0-50cm adjustable, equipped with 1000g drop weight and Φ 8mm punch, Impact depth 2mm, can accurately determine the material resistance to Impact performance.

$ 228.00

Impact height up to 120 cm, using 1000g standard hammer body, no secondary rebound phenomenon after impact, to ensure accurate and reliable test results.

$ 259.00

Impact height 0-100cm adjustable, equipped with 1000g drop weight and Φ 8mm punch, Impact depth 2mm, can accurately determine the material anti-Impact performance.

$ 286.00

20KN High Accuracy Dynamic Force Sensor, 1000mm Adjustable Impact Height, Special Metal Head Die and Protection System for Automatic Positioning and Data Collection to Ensure Accurate and Safe Testing.

$ 2341.00

Using 1kg weight free fall impact, impact height adjustable range 0-50cm, equipped with φ 8mm punch and φ 15mm die base, can carry out positive and negative impact test.

$ 164.00

Impact height of 120 cm, hammer mass 1000g, no secondary rebound phenomenon after impact, punch diaMeter 16mm, can accurately determine the impact strength of the paint film.

$ 370.00

Impact method using drop ball, test height range of 50-1000mm, equipped with four radius Impact head and 300-1000g weight, can accurately evaluate the material anti-Impact performance and fracture.

$ 933.00

Impact specimens with semi-spherical punches are used for energy consumption measurement to evaluate anti-Impact performance. Impact energy range is 3J, Impact speed is 2.5m/s, and it is suitable for a variety of film and paper tests.

$ 1348.00

Impact height range is adjustable from 0-100cm, equipped with 1000g drop weight and Φ 8mm punch, accurate impact testing is achieved through mechanical structure, and the operation is stable and reliable.

$ 243.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Selection of impact head diameter and drop hammer mass combination for paint film impact tester
When selecting the impactor diameter and drop hammer mass for a paint film impact tester, the key is to balance the impact energy and pressure.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.