Ultrasonic Non-Metal Flaw Detector

Ultrasonic non-destructive testing instruments generate high-frequency sound waves through piezoelectric crystals, which are transmitted into the material. When encountering defects, the waves reflect back as echoes and are received. The instrument analyzes the characteristics of the echoes to locate internal flaws such as cracks and bubbles in the material. It is used to assess the internal quality of non-metallic components like concrete, plastic, and ceramics.
Selection
When selecting, consider the acoustic properties of the material to match the probe frequency, and let the detection depth determine the power range. Choose between pulse-echo or through-transmission modes based on the type of defect. Pay attention to the instrument's waterproof and dustproof rating to ensure compatibility with the on-site environment, and ensure the user interface aligns with the operators' usage habits.

Terms

Standards

Instruments

With ten independent flaw detection channels, the gain range is 120dB, the frequency band is 0.4~ 20.0MHz, and it supports automatic generation of DAC Linear dispersion and 500 data storage for efficient defect identification.

$ 1897.00

With DAC Linear dispersion automatic generation function, transmission Frequency up to 1000Hz, support 6 Meters detection range and 10 independent flaw detection channels, real-time dynamic video recording and automatic measurement crazing depth.

$ 2139.00

With 130dB high gain and Automatic calibration function, support 100 independent flaw detection channels and 1000 waveform storage, Scanning range 0-10000mm, to meet the needs of a variety of material flaw detection.

$ 1587.00

With 16 flaw detection channels and 0.5~ 20MHz Frequency range, it supports Automatic calibration probes and generates DAC Linear dispersion. High Sampling rate and low noise design meet a variety of operating conditions inspection needs.

$ 1172.00

With 100 flaw detection channels and 300 graphics storage capacity, support three probe modes and automatically generate DAC Linear dispersion, waterproof and dustproof design to adapt to harsh environments, Operating temperature range -27~ 70 ℃.

$ 2946.00

Scanning range 0-6000mm, 100 independent flaw detection channels, support Automatic calibration and defect echo positioning, with high-brightness color display and three-proof design, adapt to various complex working environments.

$ 1816.00

Scanning range 0-10000mm, working time 8 hours, waterproof and dustproof function, support 100 flaw detection channels and three probe modes, can automatically generate DAC Linear dispersion and store 300 inspection data.

$ 2623.00

With a wide frequency range of 64Hz-2MHz, it can detect longitudinal crazing and transverse defects, adapts to a variety of Probe types, supports automatic phase analysis and zero correction functions, and is suitable for high-speed inspection environments.

$ 7335.00

Detection range 0-1000mm, dynamic range is greater than 36dB, with Automatic calibration and gate alarm function, support for a variety of working modes of straight oblique probes, compact and portable for field operations.

$ 3268.00

With 15 independent flaw detection channels and Automatic calibration function, the near-field blind area is small to meet the thin-walled tube detection, the working Frequency is 0.4MHz~ 15MHz, the Continuous Operating Time is more than 8 hours, and the waterproof, oil-proof and dust-proof design is supported.

$ 1640.00

Scanning range 0-10000mm, working time 8 hours, waterproof and dustproof function, support 100 flaw detection channels and three probe modes, can automatically generate DAC Linear dispersion and store 300 A-shaped graphics.

$ 3268.00

Frequency range 50Hz~ 12MHz, gain 0~ 90dB continuously adjustable, with relatively independent test channels and a variety of Display modes.

$ 8949.00

Equipped with 10 independent flaw detection channels and 110dB gain range, supports DAC Linear dispersion automatic generation and 500 data storage, adopts 5.5-inch EL flat screen display, weighs only 1.6kg and is easy to carry, and can work in -20 ℃~ 50 ℃ environment.

$ 4027.00

2000Hz repeability Frequency and 640 * 480 Display resolution, support unlimited video playback function, Automatic calibration of Probe paraMeters to improve detection accuracy, suitable for all kinds of workpiece defect identification.

$ 1114.00

Using ultrasonic technology nondestructive measurement, up to 3 layers of coating system measurement range 50~ 3800 μ m, error +/- 3%, with weatherproof design and high capacity Data storage function.

$ 3724.00

Articles

How to choose a single-column electronic universal testing machine based on the maximum test force
This article introduces how to select a single-column electronic universal testing machine based on the maximum test force. First, determine the strength range according to the material type and standard, such as plastics, metals, etc. Then, calculate the maximum force based on the tensile strength and specimen area, and multiply it by a safety factor of 1.3 to 1.5.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.