Measurement range from 10000 to 50000cSt is designed using Ubbelohde DIN standard, and accurate measurement is achieved based on the principle of capillary tubing flow time and viscosity.
Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.
Ubbelohde ASTM standard design, viscosity measurement range of 10-50cSt, based on capillary tubing flow time and viscosity proportional principle, to ensure measurement accuracy and Repeatability.
Ubbelohde ASTM standard design, viscosity measurement range of 2~ 10cSt, based on the principle of capillary tubing flow time proportional to viscosity, to ensure accurate and reliable measurement.
With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.
Ubbelohde ASTM standard design, viscosity measurement range 6000-30000cSt, based on capillary tubing flow time and viscosity proportional principle, suitable for high temperature and high viscosity fluid determination.
Ubbelohde ASTM standard design, viscosity measurement range of 600-3000cSt, based on the principle of capillary tubing flow time and viscosity proportional to achieve accurate measurement.
Ubbelohde ASTM standard design, viscosity measurement range of 200-1000cSt, based on capillary tubing flow time and viscosity proportional principle, suitable for a variety of liquid sample analysis.
Ubbelohde ASTM standard design, viscosity measurement range of 20000-100000cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity, to ensure accurate determination of high viscosity liquids.
Ubbelohde ASTM standard design, viscosity measurement range of 2000 to 10000cSt, based on capillary tubing flow time and viscosity proportional principle, to ensure High Accuracy.
Using Ubbelohde DIN size I specification, viscosity measurement range of 2~ 10cst, based on the principle of capillary tubing flow time and viscosity proportional ratio, accurate measurement is achieved.
Ubbelohde DIN standard design, viscosity measurement range of 10~ 50cSt, based on capillary tubing flow time and viscosity proportional principle, to ensure accurate determination of liquid kinematic viscosity.
Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.
Ubbelohde DIN standard design, viscosity measurement range of 6-30cSt, based on the principle of capillary tubing flow time is proportional to viscosity, suitable for accurate determination of a variety of liquid samples.
Ubbelohde DIN standard design, viscosity measurement range of 100-500cSt, based on the principle of capillary tubing flow time proportional to viscosity, to ensure accurate determination of liquid kinematic viscosity.