Low-temperature Mixer

The low-temperature mixer uses a refrigeration system to lower the temperature of the mixing chamber, maintaining the materials at a low temperature during the mixing process to prevent denaturation or volatilization of heat-sensitive materials. It is used in processes such as coatings and inks that require low-temperature mixing to ensure component stability and controllable reactions.
Selection
When selecting, it is necessary to match the material viscosity with the stirring power, confirm that the temperature control range covers the process requirements, consider the corrosion resistance of the materials, evaluate the sealing to prevent volatilization, verify that the container capacity matches the production scale, and check the convenience of the operation interface.

Terms

Standards

Instruments

Temperature range -5~ 100 ℃, Temperature Fluctuation and Uniformity up to +/- 0.05 ℃, support a variety of temperature control media, with RS485 interface remote control and multiple safety protection functions.

$ 4592.00

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Using fluorine-free refrigeration system and mirror stainless steel liner, temperature range -40~ 65 ℃, with microcomputer intelligent control and independent temperature limit alarm function, support multi-stage programming and RS-485 communication interface.

$ 5245.00

Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.

$ 3301.00

Using stepless speed regulation technology, Speed range 0~ 2800rpm, turnover diaMeter 4mm, support point and continuous Operating Mode, high performance motor to ensure rapid mixing and low noise.

$ 208.00

Fixed speed 2800RPM, eccentric spherical shaft design to ensure uniform mixing; TPU material work surface wear-resistant and corrosion-resistant, suitable for a variety of testtube specifications; compact size and low power consumption, suitable for long-term high-speed work.

$ 177.00

With 0-100 ℃ precise temperature control and 200-1800rpm oscillation function, metal module to avoid pollution, support multi-point operation and timing settings, DC brushless motor drive maintenance-free.

$ 1332.00

Can achieve -80 ℃ low temperature control, built-in two-stage magnetic stirring system, Speed range 100-1200RPM, equipped with high temperature and over-temperature protection functions, environmentally friendly refrigerant to ensure safe operation.

$ 4222.00

Metal module to avoid sample contamination, temperature control accuracy of +/- 0.5 ℃, speed range of 200-1800rpm, support multi-point operation and power failure automatic recovery function.

$ 861.00

Adopting stepless speed regulation technology, the maximum speed is 2800RPM, the eccentric spherical shaft design is easy to install, the TPU countertop is wear-resistant and corrosion-resistant, compact in size and low in noise, suitable for high-speed mixing operations.

$ 198.00

Adopt two-stage Compressor cascade refrigeration technology implementation -40 ℃ low temperature, PID temperature control with proportional refrigeration technology to improve the temperature Stability to +/- 0.5 ℃, DC brushless motor supports 100-1200RPM stepless speed regulation, with a variety of alarm and automatic recovery function.

$ 1805.00

32 5ml centrifuge tubes can be installed vertically on both sides, using a vertical installation design, suitable for HT-X100 swirl/spin Mixer, improving Sample Handling efficiency.

$ 149.00

With mixing oscillation incubate three-in-one function, temperature accuracy up to +/- 0.5 ℃, Speed range 200-1800rpm, metal module to avoid pollution, support 5 point program operation and power failure automatic recovery.

$ 809.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.

$ 8497.00

Adopt two-stage Compressor cascade refrigeration technology implementation -40 ℃ low temperature, equipped with PID temperature control technology to ensure Temperature Stability +/- 0.5 ℃, DC brushless motor supports 100-1200rpm stepless speed regulation, with automatic alarm and power failure recovery function.

$ 1805.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.