Paint Grinding Mixer

The paint grinding mixer uses high-speed rotating grinding media to shear and break up pigment agglomerates, ensuring uniform dispersion of pigments in the resin solution. This equipment is used in the pigment dispersion process during paint production to guarantee color consistency and covering power of the coating.
Selection
When selecting, consider the viscosity of the material to match the motor power, determine the type of grinding media based on particle size requirements, choose the barrel capacity according to production volume, select the material of contact components based on the corrosiveness of the material, and determine the equipment installation method in conjunction with the available space.

Terms

Standards

Instruments

The use of diamond sanding needles can flatten the surface of the grinding wheel, improve the utilization rate of abrasive wheels, and is equipped with a water supply system to support wet grinding and dry grinding. The size of abrasive wheels is about 250 × 30 × 32mm, and the Rotation speed is 1400rpm.

$ 1239.00

Double Tank grinding design, vibration speed 60-1800rpm, discharge particle size up to 5~ 10μm, support dry grinding, wet grinding and low temperature grinding, suitable for heat sensitive materials and minimal liquid nitrogen consumption.

$ 5540.00

The double Tank design is used to achieve high-throughput grinding, the vibration speed is adjustable from 60 to 1800rpm, and the discharge particle size is 5 to 10 μm. It supports dry grinding, wet grinding and low temperature grinding, and effectively protects the molecular structure of heat-sensitive materials.

$ 5697.00

With double Tank grinding and 1-30Hz vibration Frequency adjustment, support low temperature grinding protection heat sensitive material, discharge particle size up to 5~ 10μm, can process more than 10 samples at a time and grinding time only 1-3 minutes.

$ 5660.00

Using large-screen touch screen operation, intelligent control of grinding time and speed, grinding results are highly repeatability. The dual-Tank design supports high-throughput processing, and the discharge particle size can reach 5~ 10 μm. It is suitable for heat-sensitive materials and consumes very little liquid nitrogen.

$ 5237.00

Using double Tank grinding design, vibration speed 60-1800rpm, discharge particle size up to 5~ 10μm, support low temperature grinding protection of heat sensitive materials, a processing of more than 10 samples, grinding time only 1-3 minutes.

$ 5663.00

Double Tank grinding design, vibration speed 60-1800rpm, discharge particle size up to 5~ 10μm, support low temperature grinding protection of heat sensitive materials, processing multiple samples at one time and high Repeatability.

$ 5610.00

High performance motor, Power 750W, Speed range 0-8000rpm, with dispersion, grinding, stirring, mixing multi-function, closed work to reduce pollution, Modular design and easy maintenance.

$ 730.00

Using 60-1800rpm vibration speed, the discharge particle size can reach 5~ 10μm, support dry grinding, wet grinding and low temperature grinding, suitable for heat-sensitive materials and minimal liquid nitrogen consumption, can handle more than 10 samples at a time.

$ 5610.00

With 60-1800R/min vibration speed and 1-30Hz Frequency range, support dry grinding, wet grinding and low temperature grinding, can handle feed ≤ 8mm sample to 5~ 10μm particle size, suitable for thermal materials and low liquid nitrogen consumption.

$ 5665.00

With dry grinding and wet grinding dual test function, friction Frequency four-speed adjustable (21/42/85/106cpm), support 0~ 99999 automatic shutdown, in line with JIS-5071-1 and other standard requirements.

$ 783.00

The three-phase asynchronous motor has high spark-free safety performance, can handle high viscosity materials and work continuously, the grinding medium is 1.6-1 zirconia beads, and the fineness of grinding is good and easy to clean.

$ 1038.00

Single disc design integrated pre-grinding grinding polishing function, support stepless speed regulation 100-1000rpm and four speed regulation, pressure range 35-150N, equipped with electromagnetic clutch locking and automatic cleaning system, smooth and safe operation.

$ 4914.00

Speed range 300 to 1000rpm, equipped with chilled down water pipe and grinding disc flushing function, leak-proof spindle design to improve bearing life, suitable for wet grinding and a variety of sample processing.

$ 1418.00

The three-phase asynchronous motor is safe and spark-free, can handle high viscosity materials and support long-term continuous work, grinding basket volume 1.8L, speed range 0~ 3000rpm/min, to achieve efficient dispersion and refinement of grinding.

$ 3785.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.