Haze Detector

The haze meter quantifies the haze value of materials by projecting a parallel light beam onto transparent materials and measuring the ratio of the scattered luminous flux deviating more than 2.5° from the incident direction to the total transmitted luminous flux. It is used to detect the turbidity of transparent and translucent materials such as plastic films and glass.
Selection
When selecting, focus on measurement standards that comply with specifications such as ASTM D1003, with a measurement range covering 0-100% haze value. Ensure the integrating sphere size and sample holder meet daily testing needs. Consider instruments with repeatability errors of less than 0.1%, equipped with calibration certificates and standard haze plates. The operation interface should be intuitive, and the sample clamping mechanism must accommodate materials of varying thicknesses.

Terms

Standards

Instruments

The PD array Detector meets the CIE V (lambda) 2 degree Visual Response, the haze Repeatability is within 0.15, and the open sample compartment supports vertical horizontal testing to adapt to different thickness samples.

$ 961.00

The PD array Detector is used to achieve 0.01 unit haze resolution, the open sample compartment supports vertical and horizontal dual-mode testing, and a dynamic measurement system is equipped to ensure data Reliability.

$ 1977.00

The PD array Detector is used to achieve 0.01 unit haze resolution, the open sample compartment supports vertical horizontal testing, and a dynamic measurement system is equipped to monitor environment changes to ensure data Reliability.

$ 1977.00

The PD array Detector and Φ 8mm measurement aperture are used to meet the CIE V (lambda) 2 degree visual Response, and the open sample compartment supports vertical horizontal testing. Measurement time is about 1.5 seconds, and the haze resolution is 0.01 units.

$ 1655.00

High Accuracy measurement with PD array Detector. Repeatability of haze is less than 0.05. Illuminant lifetime is more than 5 years 3 million times.

$ 1977.00

The PD array Detector is used to achieve 0.1 unit haze resolution, the open sample compartment supports vertical horizontal testing, and the integrating sphere size Φ 154mm ensures the measurement Stability.

$ 1332.00

The PD array Detector is used to achieve 0.1 unit haze resolution, and the open sample compartment supports vertical horizontal testing to adapt to various samples within 170mm thickness. Measurement time is only 1.5 seconds.

$ 1332.00

Support haze and transmittance measurement, haze resolution of 0.01 units, Repeatability ≤ 0.1 units, open measurement area can be vertically operated, equipped with a variety of fixtures to adapt to different sample forms.

$ 11337.00

The PD array Detector is used to achieve 0.1 unit haze resolution, the open sample compartment supports vertical and horizontal dual-mode testing, and the dynamic measurement system is equipped with real-time monitoring environment data

$ 1332.00

Using 360~ 780nm composite full Light spectrum LED Illuminant, equipped with 256 pixel CMOS Detector, measurement wavelength range of 360~ 780nm, interval of 10nm, to achieve haze, transmittance, chroma and other Optical inspection indicators of accurate testing.

$ 6980.00

The PD array Detector meets the CIE V (lambda) 2 degree Visual Response, the haze Repeatability is less than 0.1, and the open sample compartment supports vertical horizontal testing to adapt to multiple samples with thickness less than 170mm.

$ 1332.00

The PD array Detector meets the CIE V (lambda) 2 degree Visual Response, the measurement aperture is Φ 15mm, and the open sample compartment supports vertical horizontal testing. Illuminant and environment changes are dynamically monitored to ensure reliable data.

$ 1655.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy, the haze Repeatability is less than 0.05, supports dynamic measurement and a variety of observation Illuminants to ensure accurate and reliable data.

$ 7464.00

Using 256 pixel dual array CMOS image sensor to achieve 0.01 unit haze resolution; Equipped with dynamic measurement function, real-time monitoring of environment changes to ensure data Reliability; Open measurement area supports vertical horizontal test.

$ 7464.00

The PD array Detector is used to achieve 0.01 resolution haze measurement, the open sample compartment supports vertical and horizontal dual-mode testing, and is equipped with dynamic Illuminant monitoring to ensure data Reliability and meet various international standards.

$ 1977.00

Articles

Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
Haze Transmittance Meter for Evaluating Optical Clarity of Contact Lenses
This article introduces how a haze transmittance meter is used to evaluate the optical clarity of visual correction products such as contact lenses. Haze refers to the blurriness caused by light scattering, while transmittance reflects the material's ability to transmit light. Together, these two factors determine clarity.
Haze and transmittance integrated machine measures the quality of functional films.
This article introduces how an integrated haze and transmittance meter measures the quality of functional films. Haze refers to the degree to which a material scatters light, while transmittance reflects its overall ability to transmit light.
Haze meter measures light transmission and scattering in agricultural film.
This article introduces how a haze meter measures the light transmittance and the proportion of scattered light in agricultural films. Haze is the percentage of scattered light in the total transmitted light, while light transmittance is the ratio of transmitted light to incident light.
Haze meter for detecting haze and light transmittance of optical-grade resin
This article introduces the basic concepts, measurement principles, and practical applications of haze and light transmittance in optical-grade resin materials.
Haze meter detects the transparent scattering characteristics of optical coatings.
This article introduces how a haze meter detects the transparency and scattering characteristics of optical coatings. Optical coatings are used in fields such as displays and packaging, where their transparency and scattered light can affect product performance.
Haze meter measures the haze and light transmittance of transparent coatings.
This article introduces the method of measuring the haze and light transmittance of transparent coatings using a haze meter. Haze refers to the degree of light scattering after passing through a material, while light transmittance reflects the amount of light directly transmitted.