Probe-type Thermometer

The probe-type thermometer measures temperature by contacting the surface of an object with its metal probe. The internal thermocouple converts the temperature signal into an electrical signal, which is then displayed as a temperature value on the digital screen. It is used to measure the surface temperature of solids and liquids, and is commonly applied in processes such as injection molding, oven monitoring, and food processing to control and monitor process temperatures.
Selection
When selecting, consider that the temperature measurement range should cover usage requirements, the response speed should match the frequency of changes in the measured object, the probe material should withstand the measurement environment, the cable length should suit the operational distance, the calibration method should meet accuracy requirements, and the protection rating should be appropriate for the site conditions.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Instruments

Equipped with needle Probe for direct insertion measurement, the range covers -50 to 300 ° C, the accuracy reaches +/- 1 ° C, Repeatability +/- 1% or +/- 1 ° C, and it is small and lightweight only 60g.

$ 83.00

Foldable stainless steel probe design, temperature range -49.9~ 49.9 ℃, Accuracy up to +/- 0.5 ℃, equipped with large LCD display and Fahrenheit switching function, easy to high temperature liquid safety measurement.

$ 318.00

Dual Probe design can measure two samples at the same time, equipped with BEPS low power error prevention system to avoid wrong readings, Measurement accuracy of +/- 0.5 ℃, support K/J/T type multiple temperature sensors, waterproof design to adapt to complex environments.

$ 528.00

Using penetrating AISI 316 stainless steel Probe, temperature range -50.0~ 220 ℃, accuracy +/- 0.2 ℃, with boot Self-check function, easy to clean and suitable for semi-solid and frozen materials.

$ 262.00

Using NTC Thermistor Sensor, temperature accuracy +/- 0.2 ° C (-30.0~ 170.0 ° C), equipped with folding stainless steel Probe can penetrate semi-solid materials, with IP67 Protection Rating and a variety of automatic shutdown modes.

$ 156.00

Using NTC Thermistor Sensor, Temperature measurement accuracy +/- 0.2 ℃, equipped with 103mm penetrating stainless steel Probe, supports a variety of automatic shutdown settings, Protection Rating up to IP67.

$ 156.00

With dual measurement interfaces to detect two samples simultaneously, support a wide range of Probe types covering -200 ° C to 1371 ° C, equipped with Adjustment and backlit display to ensure measurement accuracy and ease of operation.

$ 604.00

With penetrating AISI 316 stainless steel Probe, easy to clean and insert semi-solid pRoducts. With CAL Check ™ boot self-check function, temperature accuracy of +/- 0.2 ℃, Measurement range covering -50.0~ 220 ℃.

$ 211.00

Measurement range from -50.0 to 300 ° C with Response Time of only 20 seconds. Equipped with a replaceable T-type stainless steel penetrating Probe, it meets IP65 waterproof standards and has built-in calibrate inspection and battery error prevention for measurement Stability and durability.

$ 286.00

Equipped with fixed K-type stainless steel penetration Probe, Response Time 20 seconds, IP65 waterproof standard, with CAL Check ™ calibrate inspection and battery error prevention system to ensure accurate and reliable measurement.

$ 286.00

With CAL Check ™ boot Self-check function, temperature measurement accuracy of +/- 0.2 ℃, using penetrating AISI 316 stainless steel Probe, IP65 waterproof, suitable for semi-solid and frozen material temperature measurement.

$ 199.00

With split Probe design, equipped with F and N Probe, Measurement range 0~ 1500 microns, resolution 0.1 microns, automatic identification of substrate type, support for more than 60 readings per minute, Protection Rating IP65.

$ 1476.00

Response Time of only 4 seconds, temperature range of -50.0 to 300 ℃, equipped with replaceable ultra-fast Response K stainless steel penetration Probe, with CAL Check ™ calibrate inspection and automatic shutdown function.

$ 309.00

Using 16-bit AD converter and K-type Thermocouple, sampling speed 16 times per second, Measurement range -50 ° C to 1300 ° C, support Fahrenheit switching and data retention functions.

$ 104.00

Waterproof design ensures safe use in humid environment, supports three Thermocouple Probe types, Measurement accuracy up to +/- 0.5 ℃, dual measurement interface can connect two Probes at the same time, equipped with data locking and temperature Unit switching function.

$ 749.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.