Hot and Cold Cycle Bath

The hot-cold cycling bath operates by alternating between heating and refrigeration systems, causing the sample to repeatedly change within a set temperature range. It simulates the performance changes of materials under fluctuating temperature conditions and is used to test properties such as temperature resistance, shrinkage, and expansion of products like coatings and plastics. It is commonly employed in quality control and research and development testing.
Selection
When selecting a thermal cycling chamber, consider the following: the temperature range should cover testing needs, heating and cooling rates must meet standard requirements, the inner chamber size should accommodate sample specifications, the control system should be user-friendly, materials must have corrosion resistance suitable for experimental media, safety protection features should be comprehensive, and maintenance costs along with brand service reliability are also essential factors.

Terms

Standards

Instruments

Adopt independent control structure of hot and cold box, temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, equipped with safety interlock protection and 7-inch Touchscreen controller, support long-term adjustable test.

$ 42981.00

The independent control structure of the cold and hot box is adopted, with a temperature conversion time of less than 15 seconds and a temperature recovery time of less than 5 minutes. It is equipped with multiple safety interlock protection and standard lead hole design to ensure efficient and safe testing.

$ 34606.00

With the independent control structure of the cold and hot box, the temperature conversion takes only 15 seconds and the recovery time does not exceed 5 minutes. The temperature fluctuation in the sample area is controlled within +/- 0.5 ° C, the load-bearing capacity is up to 40kg, and it is equipped with safety interlock protection and 7-inch Touchscreen controller.

$ 38608.00

The integrated design does not require a cold water tower, with dual pump dual temperature control function, cooling capacity of 600W and temperature Stability of +/- 1.0K, supports multiple Safety protection and remote Communication interface to ensure reliable operation of the equipment.

$ 1498.00

Temperature range -25 ℃, temperature control accuracy +/- 1 ℃, can simulate the natural low temperature environment for bending test, observe material changes, determine the degree of cold resistance.

$ 6770.00

Adopting independent control design of hot and cold box, the temperature conversion time does not exceed 15 seconds, and the recovery time is within 5 minutes. Equipped with safety interlock function and standard lead hole tube, it enhances test efficiency and operation safety.

$ 29120.00

The equipment has 200x200mm hot pressing area, temperature control accuracy +/- 2 ℃, heating temperature up to 250 ℃. Using light curtain protection and safety protection design, the upper and lower templates have high parallelism, and the hot pressing time, temperature and pressure can be adjusted.

$ 4430.00

The temperature conversion time only takes 15 seconds, the recovery time does not exceed 5 minutes, equipped with a 7-inch Touchscreen controller, with an accuracy of +/- 0.1 ° C, and an independent cold and hot box design to improve test efficiency and safety.

$ 34429.00

Temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, cold and hot box independent control does not interfere with each other, with sample area temperature fluctuation ≤ +/- 0.5 ℃ High Accuracy thermostatic performance, improve test reliability.

$ 25328.00

Adopting the independent control structure of the cold and hot box, the temperature conversion time is ≤ 15 seconds, and the temperature recovery is ≤ 5 minutes. Equipped with safety interlock protection, the temperature fluctuation in the sample area is ≤ +/- 0.5 ° C, supporting long-term stable operation.

$ 25328.00

Adopting an independent control structure of a cold and hot box, the temperature conversion time is less than or equal to 15 seconds, the temperature recovery time is less than or equal to 5 minutes, and it has the ability to accurately control the temperature in the sample area with a temperature fluctuation of less than or equal to +/- 0.5 ° C, supporting an adjustable test time of 9999 hours.

$ 32734.00

Equipped with powerful pressure suction pump and external Bath connection port, temperature control accuracy +/- 0.1 ℃, pump flow 4L/min, with over-temperature, low temperature sound and light tracking alarm and liquid level protection function.

$ 1877.00

Adopting independently controlled hot and cold box structure, the temperature conversion time does not exceed 15 seconds, the recovery time is within 5 minutes, and it is equipped with a 7-inch Touchscreen controller with an accuracy of +/- 0.1 ° C, supporting a sample load of 20kg, suitable for a variety of testing needs.

$ 22471.00

The independent control of the hot and cold box realizes three uses in one box, the temperature conversion time is ≤ 15 seconds and the recovery time is ≤ 5 minutes, the temperature fluctuation in the sample area is ≤ +/- 0.5 ° C, and it is equipped with multiple safety interlock protection and 7-inch Touchscreen control.

$ 38414.00

Equipped with powerful pressure suction pump and imported Compressor, temperature control accuracy of +/- 0.1 ℃, support external Bath connection, with over-temperature alarm and liquid level protection function, pump flow 4L/min to ensure stable circulation.

$ 969.00

Articles