Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable, support 3~ 100 times/h ventilation volume adjustment, to meet a variety of aging test needs.
Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, using stainless steel liner and forced circulation system, with automatic ventilation function, ventilation 8~ 20 times/hour adjustable, suitable for material aging test.
With 5~ 200 times/hour air volume adjustment, temperature control accuracy +/- 0.5 ℃, liner with 1.0mm stainless steel plate, with dynamic turntable and high temperature protection system, suitable for material aging test.
Using nitrile rubber material, length 100mm diaMeter 20mm, with excellent oil resistance and aging performance, suitable for inks proofing operation.
300W yellowing resistant bulb provides 365-400nm wavelength ultraviolet, Temperature Uniformity +/- 1 ℃, can simulate the atmospheric environment accelerated testing, one machine multi-purpose support aging Oven function.
The 300W OSRAM bulb provides 365-400nm wavelength UV, Temperature Uniformity +/- 1 ℃, can be tested for yellowing resistance and aging at the same time, and the turntable Rotation speed 10 +/- 2rpm ensures uniform sample irradiation.
Temperature control accuracy of +/- 0.5 ℃, air change 3-150 times/hour adjustable, using SUS304 stainless steel inner box and PID automatic calculation function to ensure test Stability and data accuracy.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, temperature fluctuation is only +/- 0.5 ℃.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, Temperature Fluctuation control within +/- 0.5 ℃.
The heating wire is used to achieve rapid heating, the temperature fluctuation is only +/- 0.5 ℃, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, supports dynamic static test mode, and meets a variety of test needs.
Using heating wire and PT100 temperature transducer, Temperature Fluctuation +/- 0.5 ℃, support 0~ 999H light time setting, 360 degree swirl/spin sample holder and imported concentration Analyzer to ensure test accuracy.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360-degree swirl/spin sample holder and 12-16mm/s gas flow rate, support 0-9999 hours time setting, with leakage overtemperature multiple safety protection.
Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, with automatic ventilation system can adjust the ventilation volume 8~ 20 times/hour, sample holder can swirl/spin to ensure test uniformity.
High Accuracy PID control technology, temperature fluctuation +/- 0.5 ℃, equipped with independent ozone concentration controller long-term stable non-drift, support static tensile specimen and program operation mode.
The equipment adopts high-density fiberglass cotton insulation layer Film thickness 150mm, Temperature Uniformity up to +/- 1 ℃, with automatic ventilation system adjustable ventilation volume 8-20 times/hour, sample holder can be swirl/spin design to enhance test uniformity.