Paint Hot and Cold Test Chamber

The paint hot and cold test chamber simulates temperature-changing environments through cooling and heating systems, allowing paint samples to cycle within a set temperature range. It is used to observe the physical changes of coatings under alternating cold and hot conditions, thereby testing the temperature resistance and stability of the paint.

Instruments

Adopt independent control structure of hot and cold box, temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, equipped with safety interlock protection and 7-inch Touchscreen controller, support long-term adjustable test.

$ 42981.00

The independent control structure of the cold and hot box is adopted, with a temperature conversion time of less than 15 seconds and a temperature recovery time of less than 5 minutes. It is equipped with multiple safety interlock protection and standard lead hole design to ensure efficient and safe testing.

$ 34606.00

With the independent control structure of the cold and hot box, the temperature conversion takes only 15 seconds and the recovery time does not exceed 5 minutes. The temperature fluctuation in the sample area is controlled within +/- 0.5 ° C, the load-bearing capacity is up to 40kg, and it is equipped with safety interlock protection and 7-inch Touchscreen controller.

$ 38608.00

Temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, cold and hot box independent control does not interfere with each other, with sample area temperature fluctuation ≤ +/- 0.5 ℃ High Accuracy thermostatic performance, improve test reliability.

$ 25328.00

The temperature conversion time only takes 15 seconds, the recovery time does not exceed 5 minutes, equipped with a 7-inch Touchscreen controller, with an accuracy of +/- 0.1 ° C, and an independent cold and hot box design to improve test efficiency and safety.

$ 34429.00

Adopting independent control design of hot and cold box, the temperature conversion time does not exceed 15 seconds, and the recovery time is within 5 minutes. Equipped with safety interlock function and standard lead hole tube, it enhances test efficiency and operation safety.

$ 29120.00

Adopting the independent control structure of the cold and hot box, the temperature conversion time is ≤ 15 seconds, and the temperature recovery is ≤ 5 minutes. Equipped with safety interlock protection, the temperature fluctuation in the sample area is ≤ +/- 0.5 ° C, supporting long-term stable operation.

$ 25328.00

Adopting an independent control structure of a cold and hot box, the temperature conversion time is less than or equal to 15 seconds, the temperature recovery time is less than or equal to 5 minutes, and it has the ability to accurately control the temperature in the sample area with a temperature fluctuation of less than or equal to +/- 0.5 ° C, supporting an adjustable test time of 9999 hours.

$ 32734.00

Adopting independently controlled hot and cold box structure, the temperature conversion time does not exceed 15 seconds, the recovery time is within 5 minutes, and it is equipped with a 7-inch Touchscreen controller with an accuracy of +/- 0.1 ° C, supporting a sample load of 20kg, suitable for a variety of testing needs.

$ 22471.00

The independent control of the hot and cold box realizes three uses in one box, the temperature conversion time is ≤ 15 seconds and the recovery time is ≤ 5 minutes, the temperature fluctuation in the sample area is ≤ +/- 0.5 ° C, and it is equipped with multiple safety interlock protection and 7-inch Touchscreen control.

$ 38414.00

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Temperature range -25 ℃, temperature control accuracy +/- 1 ℃, can simulate the natural low temperature environment for bending test, observe material changes, determine the degree of cold resistance.

$ 6770.00

The paint film adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel was 80mm. The integrity of the paint film was evaluated according to seven grades, and the operation was simple and reliable.

$ 267.00

The equipment has 200x200mm hot pressing area, temperature control accuracy +/- 2 ℃, heating temperature up to 250 ℃. Using light curtain protection and safety protection design, the upper and lower templates have high parallelism, and the hot pressing time, temperature and pressure can be adjusted.

$ 4430.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Articles

Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.
Technical Differences Between Two-Chamber and Three-Chamber Thermal Shock Test Chambers
The thermal shock test chamber is used to test a product's resistance to sudden temperature changes, primarily through two methods: the two-chamber method and the three-chamber method. What are the differences between them? This article will tell you!
The difference between thermal shock test chambers and constant temperature and humidity chambers
This article compares the differences between thermal shock test chambers and constant temperature and humidity chambers in terms of working principles, key performance, and applications.